15
8. FRONT PANEL FUNCTIONS AND CONTROLS - H-08EX
Fig.8
1. POWER
Main power switch
9. REAR PANEL FUNCTIONS AND CONTROLS - H-08EX
Fig.9
1. MAINS POWER INPUT
Connect main unit to 230 V AC 50/60 Hz mains.
8 A fuse socket.
2. EXPANDER OUTPUT
6 inputs for President/Delegate units. Each line can be connected to up to 30 stations (do not
connect more than 30). One H-08EX can manage up to
60
stations.
3. In-line Power Switches
After connecting the stations to the system, set the switches of the lines involved on the “I” position.
The LED light will indicate that the line is powered.
4. EXSPANDER LINK IN
Connect this input to one of the 4 H-7300 ouputs using the cable provided (
fig. 2, ref. 2
)
5. EXSPANDER LINK OUT
Connect this output to the next expansion unit input using the provided cable (
fig. 9, ref. 4
). There
is no limit to the number of expansion units that can be connected, yet the total number of
manageable microphone stations must not exceed 254.