5.3
Connecting LXNAV TrafficView
TrafficView can be connected to any Flarm or ADS-B device with TrafficView cable.
5.4
Installation of options
Optionally
,
more TrafficView devices can be connected through
a
Flarm Splitter.
5.4.1
Ports and Wiring
5.4.1.1
LXNAV TrafficView port (RJ11)
1 2 3
4 5 6
1 2 3 4 5 6
Pin numbers Pin numbers
Pin number Description
1
(Power inp
ut) 12VDC
2
3
GND
4
(input) Data in
RS232
– receive line
5
(output)
Data out RS232
– transmit line
6
Ground