background image

Notification

Dear Users,
Thank you for your purchase of RU 1400 Refraction Unit. Please take time to read our 

user’s manual carefully before use. 

This guarantees you to make full use of this unit and prolongs the operation life of 
this unit.

Precautions

If you have detected abnormal heat, smoke, noise or smell, immediately stop using 

the product.

In the event of an abnormality, turn off the power and disconnect the power plug from 
the power socket. Continuing to use the product may result in electric shock or fire.

Observe the instructions given below regarding the power cable:

•     Be sure to use the supplied or specified power cable.
•     Do not modify, forcibly bend, kink or pull the power cable.
•     When disconnecting the power cable from the AC outlet, be sure to hold the cable 
       by the plug.
       Pulling the cable may cause wire breakage or shot circuit, resulting in fire or electric 

       shock.

•     Do not connect or disconnect the plug of the power cable to/from the AC outlet 
       using wet hands.

       Doing so may result in electric shock.

•     Do not touch the product with wet hands while the power cable is connected    

       to the AC outlet.
       Doing so may result in electric shock.

•     If the product will not be used for a long period, disconnect the power cable   
       from the power source. Leaving the cable connected to the power socket for    
       a prolonged period will consume electricity and may result in heating.

Содержание RU-1400

Страница 1: ......

Страница 2: ... sure to use the supplied or specified power cable Do not modify forcibly bend kink or pull the power cable When disconnecting the power cable from the AC outlet be sure to hold the cable by the plug Pulling the cable may cause wire breakage or shot circuit resulting in fire or electric shock Do not connect or disconnect the plug of the power cable to from the AC outlet using wet hands Doing so ma...

Страница 3: ...Content 1 Package List 4 2 Name of Parts 7 3 Assembly Process 9 4 Default Circuit Settings and Adjustment 15 5 Operation 16 6 Possible failure and Repair 18 7 Wiring Diagram 19 8 Specifications 22 ...

Страница 4: ...1 Package List 4 ID 1 2 3 4 5 Name MainPart including Base Liftpart and Operating Board Rocker ShortRod LongRod Lamp Qty 1 1 1 1 1 Figure ...

Страница 5: ...5 Figure ID 6 7 8 9 10 11 12 Name Back Cannula Hex Socket Cap Screw ISO 4762 M8X120 Projector Flat and Countersunk Flat Head Screw Power Cable Communication Cable Fuse 5A Qty 1 1 1 1 ...

Страница 6: ...Figure ID 13 14 15 16 Name Hex Spanners Wrench Manual Acceptance Certificate Qty 4 1 1 1 6 ...

Страница 7: ...Fig 1 Components diagram 1 2 Name of Parts Refer to figure 16 and Figure 1 to understand the instrument s components 1 2 3 4 5 6 7 8 9 10 11 12 13 23 22 21 20 19 18 17 16 15 14 7 ...

Страница 8: ...t Voltage Adjustment 8 Chiar down up botton 9 Cushion 10 Chair Frame 11 Chair Cover 12 Baffle 13 Footboard 14 Base 15 Mainframe 16 Panel 17 Handle 18 ShortRod 19 Cannula 20 Rocker locker 21 LongRod 22 Connector Pipe 23 Lamp 24 Screws 25 Power Switch 26 HorizontalRod on Rocker 27 Headrest 28 Lifting Switch 24 25 26 27 28 8 ...

Страница 9: ...o you can open it s back fig 3 Fig 3 Unfix the back 3 Unscrew the screw and washer on the end of the ShortRod fig 4 Fig 4 Unscrew screw and washer 4 Fit the ShortRod on the MainPart according to the place showed in figure 5 In this step do not make the screw completely fixed so that you can adjust the position of the ShortRod 9 ...

Страница 10: ...he MainPart with the same way as step 3 4 you should unscrew the screw and washer at the end of the LongRod see fig 6 and the four screws on the other end of it fig 7 See Figure 6 8 Fig 6 Unscrew the screw and washer on LongRod Fig 7 Unscrew the four screws 10 ...

Страница 11: ...ket Cap Screw ISO 4762 M8x120 into the ShortRod Cannula and the LongRod Before fixing the screw you need to adjust the ShortRod and the LongRod keep them vertical to the ground Fig 9 Fig 9 Assembly the Cannula 7 Pull out the wires from the Lamp connect each wire to the wire with the same color in the LongRod Fig 10 Fig 10 Connect Wires 11 ...

Страница 12: ...9 After the ShortRod LongRod and the Lamp has been set up you should adjust their position to keep the ShortRod and LongRod vertical to the ground At last tighten each screws fig 5 8 9 10 Unscrew the three bolts and nuts on the chair of the MainPart see figure 12 Fig 12 Unscrew three bolts and nuts Three bolts and nuts 11 Align the three holes on the Back and their corresponding holes on the chair...

Страница 13: ...an run softly and comfortably See figure 14 Fig 14 Assembly the Rocker 13 To install the Projector Flat with the Countersunk Flat Head Screw Keep the length of the power plug wire 260mm see figure 15 On the back of Flat there was fixed a universal you need to test it s swing motion 13 ...

Страница 14: ...g wire respectively according to the connection diagram see figure 16 Fig 13 Connection diagram Lighting wire Projector wire AC Input 15 Power on to test the wire connection If connection is correct fix the back of MainPart fig 17 make sure that the two screws are not screwed so tight Fig 17 Fix the back of the MainPart 14 ...

Страница 15: ...rsa Fig 18 Adjust spring strain Wrench 19 Set up the optometry facilities on the operating Board connect its plugs into the outlet under the operating Board 20 You can connect the wires for the two DC outputs on operating board The two DC outputs can be adjusted to 3V 6V 9V 12V or 24V You can adjust on the mainboard default is 12V 4 Default Circuit Settings and Adjustment 1 The default setting of ...

Страница 16: ...orks Fig 19 Mainboard Chart 1 2 3 5 Operation 1 Power on the facility and press the POWER button on the Panel No 16 in fig 1 the facility will stand by 2 Press down the handle No 17 in fig 1 on the Operating Board No 6 in fig 1 you can move the Board to the left or right When the Board moves to left the DC output on left default is 12V power on and the output on right is shut off vice versa 3 Pres...

Страница 17: ...eight of the chair do it as step 3 you should refer to a manual of the Eyesight Detector if you do not know how to operate it 6 After the eyesight examination you must loose the handle of the Rocker move the Rocker to its onginal place and lock it 7 Here is a function list of the buttons on the panel see Fig 20 1 Lamp ON OFF 2 Projector ON OFF 3 Computer Outlet ON OFF 4 Chair down up buttons 5 Pow...

Страница 18: ...or if the line is kept well a It shows that some place is leaked and the unilateral plug needs to be changed Please contact with the factory or the maintenance place to change b It has low temperature in winter the density of the oil is high so it might happened it will be OK in ten minutes or so after it is started Contact with the factory or the maintenance place let the professional check the i...

Страница 19: ...7 Wiring Diagram The electric principle map 19 ...

Страница 20: ...The electric system map 20 ...

Страница 21: ...The line sketch map 21 ...

Страница 22: ... rotation for table Table rnovement Angle of rotation for chair Lifting height for chair Loading for chair Lifting height for pillow Backrest obliquity Table and Case using complex material Color Electrical Parameters 110V 220V AC 50Hz 60Hz 140W 220V AC 15W 110V 220VAV 5A 250V AC 1W 2KV S1 Input Voltage Engine power Light Luminaire Fuse Power without load PressureTest Working mode 22 ...

Страница 23: ...250V 30 C 50 C less than 90 1 5N Nature cooling Main Wire Working Temperature Relative Humidity Force of Pressing key Cooling mode Installation Dimension 1400mm x 1000mm x 1990mm 98Kg Figure size Weight 23 ...

Страница 24: ...sion or limitation of incidental or consequential damages Accordingly the above limitation may not apply to you Every effort has been made to ensure the accuracy of this manual However LUXVISION makes no warranties with respect to the documentation and disclaims any implied warranties of merchantability and fitness for a particular purpose LUXVISION Inc shall not be liable for any errors or for in...