Model #
A
B
C
L-BV-3
14
21
32
L-BV-4
14
23
32
L-BV-5
14
23
36
L-BV-6
14
25
36
ALL MEASUREMENTS ARE IN INCHES
5“
10“ (254mm)
38“ (965mm)
LBV-Venting
Exiting fireplace (Masonry or factory built)
The model Luxor is intended for installation into masonry or listed factory built fireplaces.
Masonry fireplaces must be built according to the requirements of the standards for chimneys,
fireplaces, vents, and solid fuel burning appliances, NFPA 211 (latest edition) or the applicable
National, Provincial, State , or Local codes. The figure below shows the minimum install
dimensions for the model Luxor.
Check that step does not interfere with
install dimension or vent pipe.
If mantle is combustible, see below
for allowable clearances.
A
B
C
Note: Measurement taken from under side
of mantel to finished floor surface that the
unit is sitting on.
Page 6
9”
Note: The model Luxor is certified without requiring a hearth projection,
although local codes may require a minimum hearth projection.
WARNING: Any door system or covering installed in front of the LBV Series
inserts must NOT restrict the flow of air required for proper operation.
FDM’s Custom Wire-Mesh Doors are designed and tested for optimum
operating conditions with all models of Luxor Units.
If the fireplace is installed behind glass doors and safety switch must be in
place that will not allow fireplace operation unless the doors are opened.
The minimum distance between the door and the fireplace is 2”. The door
top & side inside dimension must not cover the insert front outside
dimension by more than 1” & 21/2” on the bottom.