background image

Spare Parts

Part No.

Description

FD-101

#42 Orifice

FD-102

#38 Orifice

FD-103

SIT Pilot Assembly

FD-104

SIT Gas Valve

LDBV-DR 3 Door Assembly  
LDBV-DR 4 Door Assembly
LDBV-DR 5 Door Assembly
LDBV-DR 6 Door Assembly

Fan Components

FF-101Fan kit
FF-102 Heat Sensor

Log Set

SIT Pilot Assembly

Variable Speed Fan

Parts List

Page 15

WARNING: Failure to position the parts in accordance with the instructions or failure to 
use parts specifically approved with this appliance may result in property damage or 
personal injury. 

Содержание LBV-3

Страница 1: ...e fire department PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING THE APPLIANCE WARNING If the information in these instructions are not followed exactly a fire or explosion may res...

Страница 2: ...s been converted for use with a gas fireplace insert only and can not be used for burning wood or solid fuels unless all original parts have been replaced and the fireplace re approved by the authorit...

Страница 3: ...ks FOR YOUR SAFETY Read before lighting DO NOT Use tools to operate controls Use only you hand to push in and turn controls DO NOT Abuse glass doors by striking or slamming shut DO NOT Clean the appli...

Страница 4: ...ance of severe burning or the possible ignition of clothing Young children should be carefully supervised when they are in the same room as the appliance Due to the high temperatures the fireplace sho...

Страница 5: ...isted and certified for the installation in the U S A and Canada under the following standards ANSI Z21 88b CSA 2 33b 2003 Heater Rated 72 minimum without the fan Please contact CFH Mfg Inc if you hav...

Страница 6: ...es not interfere with install dimension or vent pipe If mantle is combustible see below for allowable clearances Note The model Luxor is certified without requiring a hearth projection although local...

Страница 7: ...x Slide unit into the opening taking care not to damage the liner allow enough slack for final surround assembly WARNING Failure to position the parts in accordance with these diagrams or failure to u...

Страница 8: ...below for allowable clearances A B C Note Measurement taken from under side of mantel to finished floor surface that the unit is sitting on Page 6 9 Note The model Luxor is certified without requiring...

Страница 9: ...undisturbed airflow hits the outside vent terminal from any direction The figure below shows minimum vent cap clearances Check local codes for allowable vertical vent terminations Venting notes Where...

Страница 10: ...amage or personal injury Vent Installation IMPORTANT This appliances venting system requires room air for combustion which means that there should be provision to allow room air to be used in the comb...

Страница 11: ...oor to unhook assembly from the top clips Window Replacement Locate the top door channel over the top firebox relief brackets Locate the bottom two clasps and close clasps Pull the top of the window f...

Страница 12: ...grounded three prong receptacle Do not cut or remove the grounding prong from this plug CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dan...

Страница 13: ...pliance supply connection the fitter shall provide an easily accessible manual shut off valve The gas supply pipe should enter the appliance case through the opening at the right side The supply pope...

Страница 14: ...djustment Air adjustment is located beneath the firebox which is attached to the valve tray This venturi adjustment allows for fine tuning of the flame characteristics which may vary due to climate al...

Страница 15: ...rner The second segment is to sit on the small shelf at the rear of the firebox while leaning the burnt end up on the first segment as shown Lean the third segment against the top of the second segmen...

Страница 16: ...stallation pictures are with the optional Brick Set installed If you do not have the 3 piece brick set the background will be black Installation of 3 Piece Brick Set The brick sets are pre cut and sli...

Страница 17: ...sembly LDBV DR 5 Door Assembly LDBV DR 6 Door Assembly Fan Components FF 101Fan kit FF 102 Heat Sensor Log Set SIT Pilot Assembly Variable Speed Fan Parts List Page 15 WARNING Failure to position the...

Страница 18: ...ion carefully 2 Set the thermostat to the lowest setting 3 Controls are accessed by opening the bottom louver 4 Turn the manual burner switch to the OFF position 5 Push in gas control knob slightly an...

Страница 19: ...regularly as soon as you notice the buildup white film If the film is left for a longer period of time build up will bake on Once baked it is much harder if not impossible to remove 2 Never use an ab...

Страница 20: ...r poor connection from the sparker to the electrode Check for the spark shorting or arcing at other locations Check for defective piezo Check for defective or cracked electrode With the door removed t...

Страница 21: ...correct venting Incorrect aeration adjustment No power supply Thermal snap switches loose or defective Loose electrical connection Defective speed controller Defective blower Problem Frequent pilot ou...

Страница 22: ...material etc It is imperative that control compartments burners and circulating passage ways of the appliance to be kept clean To clean the logs use a soft paint brush and to clean the burner compartm...

Страница 23: ...h respect to the Luxor Limited Lifetime Warranty CFH Mfg Inc may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wh...