background image

 

B BLIND4 

V. 04 – 28/07/2021 

©AED Distribution nv 

 

Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified 
technician check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating workload limits, determining the installation 
material to be used… Have the material and the device itself checked regularly. Do not attempt to install 
the device yourself if you lack these qualifications as improper installation may result in injuries. 

 

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws. 

 

Make sure there is no flammable material within a 0.5 m radius of the device. 

 

Have a qualified electrician carry out the electric connection. 

 

Connect the device to the mains with the power plug. All devices must be powered directly off a grounded 
switched circuit and cannot be run off a rheostat or dimmer circuit, even if the rheostat or dimmer channel 
is used solely for 0 % to 100 % switching. 

 

The installation has to be approved by an expert before the device is taken into service. 

6.

 

Use 

Plug the power socket into the power supply (230 VAC, 50 Hz). This blinder is DMX-controlled via one channel. 

DMX-512 Connection 

 

When applicable, connect an XLR cable to the female XLR output of a controller (not incl.) and the other 
side to the male XLR input of the device. Multiple devices can be linked through serial linking. The linking 
cable should be a dual core, screened cable with XLR input and output connectors. 

 

Maximum recommended serial data link distance is 500 meters (1640 ft). Maximum recommended number 
of devices on a serial data link is 32 devices. 

 

DMX chain with terminator: 
A DMX terminator is recommended for installations where the DMX cable has 
to run a long distance or used in an electrically noisy environment (e.g. 
discos). The terminator prevents corruption of the digital control signal by 
electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω 
resistor between pins 2 and 3, which is then plugged into the XLR output 
socket of the last device in the chain. 

 

 

DMX Start Address Selection 

 

All DMX-controlled devices need a digital start address so that the correct device responds to the signals. 
This digital start address is the channel number from which the device starts to “listen” to the DMX 
controller. The same starting address can be used for a whole group of devices or an individual address can 
be set for every device. 

 

When all devices have the same address, all the units will “listen” to the control signal on one particular 
channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you 
set individual addresses, each device will “listen” to a separate channel number. Changing the settings of 
one channel will only affect the device in question. 

 

In case of the 1-channel mode, you will have to set the start address of the first unit to 1 (CH1), the second 
to 2 (CH2), the third to 3 (CH3), and so on. The highest start address is 512. 

 
Menu control 
Four buttons: MENU, UP, DOWN, ENTER 
Four digits display, auto switch of after 1 minute. 
 
Menu up, down as for the selection:  Addr, oL--, FLAS.  
Use ENTER  for the confirmation of your selection. Continue with the detailed setup of your selection. 
Addr: setup of the DMX start address. 
 

Axxx is shown 

 

Use the UP & DOWN buttons to adjust the start address (001 to 512) 

 

ENTER to confirm 

oL:    manual setup of the brightness 

oLxx is shown 

 

Use the UP & DOWN buttons to adjust the brightness from 0 to max (000 to 255) 

Отзывы: