background image

 

B BLIND4 

V. 04 – 28/07/2021 

©AED Distribution nv 

3.

 

General Guidelines 

Refer to the Aed Distribution® Service and Quality Warranty on the last pages of this manual. 

 

 

Keep this device away from dust and extreme temperatures. Make sure the ventilation 
openings are clear at all times. 

 

Protect this device from shocks and abuse. Avoid brute force when operating the device. 

 

 

Familiarise yourself with the functions of the device before actually using it. Do not allow operation by 
unqualified people. Any damage that may occur will most probably be due to unprofessional use of the 
device. 

 

All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to 
the device is not covered by the warranty. 

 

Only use the device for its intended purpose. All other uses may lead to short circuits, burns, electroshocks, 
lamp explosion, crash, etc. Using the device in an unauthorised way will void the warranty. 

 

Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the 
dealer will not accept responsibility for any ensuing defects or problems. 

 

A qualified technician should install and service this device. 

 

Do not switch the device on immediately after it has been exposed to changes in temperature. Protect the 
device against damage by leaving it switched off until it has reached room temperature. 

 

This device is designed for professional use on stage, in discos, theatres, etc. The device should only be 
used indoors with an alternating current of 230 VAC, 50 Hz. 

 

This lighting effect is a blinder and is designed to operate briefly at full power. Do not use this device at full 
power for longer than 10 seconds. 

 

Use the original packaging if the device is to be transported. 

 

Keep this manual for future reference. 

4.

 

Features 

 

professional DMX-controlled stage blinder for stage, clubs and studios 

 

each set of 2 lamps is separately adjustable to choose the requested angle 

 

for 4 x PAR36 DWE 650 W / 120 V lamps. 

5.

 

Installation 

Lamps 

 

Only fit or replace a lamp when the device is unplugged from the mains. 

 

Let a lamp cool down before replacing it as the temperature of a lamp can 
reach 700 °C during operation. 

 

Do not install lamps with a higher wattage than that for which this device was 
designed. 

 

Replace any deformed or damaged lamp with a lamp of the same type (see 
“Technical Specifications”): 
1.

 

Unscrew the screw at the top holding the vented lid and gently remove the 
lid. 

2.

 

Remove the old lamp and insert the new one. 

3.

 

Carefully reposition the lid and fasten the screw. 

 

Warning: Do not operate the device when the cover is open. 

 

Mounting the Device 

 

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms. 

 

The carrying construction must be able to support 10 times the weight of the device for 1 hour without 
deforming. 

 

The installation must always be secured with a secondary attachment e.g. a safety cable. 

Отзывы: