CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - With Air Handler
UNIT
MODEL
AIR
HANDLER
COIL
1
MODEL
ARI HEATING
2
47
F
17
F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
13 SEER HP WITH MV - VARIABLE SPEED
THRD18S41S1
MV12B
FC/MC18B
17.6
3.36
1.43
9.6
2.28
1.14
7.70
THRD18S41S1
MV12B
FC/MC24B
17.6
3.36
1.43
9.6
2.28
1.14
7.70
THRD18S41S1
MV12B
FC/MC30B
17.6
3.36
1.43
9.6
2.28
1.14
7.70
THRD24S41S1
MV12B
FC/MC24B
23.0
3.74
1.66
13.4
2.62
1.32
8.20
THRD24S41S1
MV12B
FC/MC30B
23.0
3.74
1.66
13.4
2.62
1.32
8.20
THRD30S41S1
MV16C
FC/MC35C
27.4
3.58
2.05
14.0
2.46
1.56
8.20
THRD30S41S1
MV12B
FC/MC43B
28.0
3.70
2.02
14.0
2.46
1.56
8.20
THRD30S41S1
MV16C
FC/MC43C
28.0
3.70
2.02
14.0
2.46
1.56
8.20
THRD36S41S1
MV16C
FC/MC43C
33.0
3.70
2.53
17.9
2.38
2.01
8.00
THRD36S41S1
MV16C
FC/MC48C
33.0
3.70
2.53
17.9
2.38
2.01
8.00
THRD42S41S1
MV16C
FC/MC48C
40.0
3.95
2.64
23.4
2.76
2.17
8.75
THRD42S41S1
MV20D
FC/MC48D
40.0
3.95
2.64
23.4
2.76
2.17
8.75
THRD42S41S1
MV16C
FC/MC60C
40.5
4.00
2.64
23.4
2.76
2.17
8.75
THRD42S41S1
MV20D
FC/MC60D
40.5
4.00
2.64
23.4
2.76
2.17
8.75
THRD48S41S1
MV20D
FC/MC60D
46.0
4.00
3.10
27.0
2.78
1.82
8.20
THRD48S41S1
MV20D
FC/MC62D
46.0
4.00
3.10
27.0
2.78
1.82
8.20
THRD60S41S1
MV20D
FC/MC62D
56.5
3.54
4.04
35.2
2.46
3.55
8.00
13 SEER HP WITH AV - VARIABLE SPEED
THRD18S41S1
AV*24
–
17.6
3.36
1.43
9.6
2.28
1.14
7.70
THRD24S41S1
AV*24
–
23.0
3.74
1.66
13.4
2.62
1.32
8.20
THRD30S41S1
AV*36
–
27.4
3.58
2.05
14.0
2.46
1.56
8.20
THRD36S41S1
AV*36
–
32.0
3.50
2.53
17.9
2.38
2.01
8.00
THRD42S41S1
AV*48
–
40.5
3.95
2.64
23.4
2.76
2.17
8.75
THRD42S41S1
AV*60
–
40.5
3.95
2.64
23.4
2.76
2.17
8.75
THRD48S41S1
AV*48
–
46.0
4.00
3.10
27.0
2.78
1.82
8.20
THRD48S41S1
AV*60
–
46.0
4.00
3.10
27.0
2.78
1.82
8.20
13 SEER HP WITH F6FP
THRD18S41S1
F6FP18
–
17.6
3.36
1.43
9.6
2.28
1.14
7.70
THRD18S41S1
F6FP24
–
17.6
3.36
1.43
9.6
2.28
1.14
7.70
THRD24S41S1
F6FP24
–
23.0
3.74
1.66
13.4
2.62
1.32
8.20
THRD30S41S1
F6FP30
–
27.4
3.58
2.05
14.0
2.46
1.56
8.20
THRD30S41S1
F6FP36
–
27.4
3.58
2.05
14.0
2.46
1.56
8.20
THRD36S41S1
F6FP36
–
32.0
3.50
2.53
17.9
2.38
2.01
8.00
THRD42S41S1
F6FP42
–
40.0
3.95
2.64
23.4
2.76
2.17
8.75
THRD42S41S1
F6FP48
–
40.0
3.95
2.64
23.4
2.76
2.17
8.75
THRD48S41S1
F6FP48
–
46.0
4.00
3.10
27.0
2.78
1.82
8.20
THRD48S41S1
F6FP60
–
46.0
4.00
3.10
27.0
2.78
1.82
8.20
THRD60S41S1
F6FP60
–
56.5
3.54
4.04
35.2
2.46
3.55
8.00
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.