445073-LTG-A-0109
4
Johnson Controls Unitary Products
— = Not applicable.
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL
W
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.
13 SEER HP WITH MV - VARIABLE SPEED
THRD18S41S1
MV12B
17
FC/MC18B
655
18.0
13.5
13.00
11.20
THRD18S41S1
MV12B
17
FC/MC24B
655
18.0
13.5
13.00
11.45
THRD18S41S1
MV12B
17
FC/MC30B
655
18.0
13.5
13.00
11.45
THRD24S41S1
MV12B
17
FC/MC24B
770
23.0
17.5
13.00
11.20
THRD24S41S1
MV12B
17
FC/MC30B
770
23.0
17.5
13.00
11.20
THRD30S41S1
MV16C
21
FC/MC35C
1095
30.0
21.7
13.00
11.50
THRD30S41S1
MV12B
17
FC/MC43B
1050
30.0
21.7
13.00
11.65
THRD30S41S1
MV16C
21
FC/MC43C
1095
30.0
21.7
13.00
11.70
THRD36S41S1
MV16C
21
FC/MC35C
1215
34.2
25.0
13.00
11.20
THRD36S41S1
MV16C
21
FC/MC43C
1215
35.0
25.6
13.00
11.60
THRD42S41S1
MV16C
21
FC/MC48C
1400
40.5
31.6
13.00
11.75
THRD42S41S1
MV20D
24
FC/MC48D
1430
40.5
31.6
13.00
11.80
THRD42S41S1
MV16C
21
FC/MC60C
1400
40.5
31.1
13.00
11.85
THRD42S41S1
MV20D
24
FC/MC60D
1430
40.5
31.6
13.00
11.90
THRD48S41S1
MV20D
24
FC/MC60D
1595
47.0
35.3
13.00
11.80
THRD48S41S1
MV20D
24
FC/MC62D
1595
47.5
35.5
13.00
11.80
THRD60S41S1
MV20D
24
FC/MC62D
1800
54.5
43.0
13.00
11.20
13 SEER HP WITH AV - VARIABLE SPEED
THRD18S41S1
AV*24
17
–
595
18.0
13.5
13.00
11.20
THRD24S41S1
AV*24
17
–
815
23.6
18.0
13.00
11.30
THRD30S41S1
AV*36
21
–
1005
30.0
21.7
13.00
11.45
THRD36S41S1
AV*36
21
–
1230
35.0
25.6
13.00
11.60
THRD42S41S1
AV*48
24
–
1440
40.5
31.6
13.00
11.80
THRD42S41S1
AV*60
24
–
1400
40.5
31.6
13.00
11.75
THRD48S41S1
AV*48
24
–
1605
47.0
35.3
13.00
11.70
THRD48S41S1
AV*60
24
–
1600
47.0
35.3
13.00
11.65
13 SEER HP WITH F6FP
THRD18S41S1
F6FP18
17
–
600
18.0
13.5
13.00
11.20
THRD18S41S1
F6FP24
17
–
600
18.0
13.5
13.00
11.20
THRD24S41S1
F6FP24
17
–
800
23.6
18.0
13.00
11.30
THRD30S41S1
F6FP30
21
–
990
30.0
21.7
13.00
11.45
THRD30S41S1
F6FP36
21
–
1000
30.0
21.7
13.00
11.45
THRD36S41S1
F6FP36
21
–
1190
34.2
25.0
13.00
11.20
THRD42S41S1
F6FP42
24
–
1430
40.5
31.6
13.00
11.80
THRD42S41S1
F6FP48
24
–
1400
40.5
31.6
13.00
11.80
THRD48S41S1
F6FP48
24
–
1600
47.0
35.3
13.00
11.70
THRD48S41S1
F6FP60
24
–
1600
47.5
35.5
13.00
11.80
THRD60S41S1
F6FP60
24
–
1800
54.5
43.0
13.00
11.20
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
UNIT
MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(Min.-max.)
W
RATED
CFM
NET MBH
SEER
1
EER
TOTAL
SENS.
THRD60S41S1
1600 - 2000
21,24
FC/MC62
1850
54.0
42.5
13.00
11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.