Johnson Controls Unitary Products
11
445073-LTG-A-0109
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. THRD24S41S1
INDOOR COIL MODEL NO.
F6FP24
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM
600
800
1000
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
24.4
26.0
26.9
29.5
30.7
26.4
26.3
28.0
30.4
31.4
28.4
26.5
29.0
31.4
32.0
S.C.
23.8
21.5
18.7
18.8
15.3
25.7
23.7
20.9
20.2
15.9
27.7
25.9
23.0
21.7
16.4
KW
1.6
1.6
1.7
1.7
1.7
1.7
1.7
1.8
1.8
1.8
1.8
1.8
1.8
1.9
1.9
75
T.C.
22.6
24.0
24.2
27.3
28.9
24.7
24.7
25.3
28.1
29.7
26.8
25.4
26.5
28.8
30.4
S.C.
22.1
20.6
17.5
17.8
14.6
24.1
22.7
19.8
19.5
15.3
26.1
24.8
22.0
21.1
16.0
KW
1.7
1.7
1.7
1.8
1.8
1.8
1.8
1.8
1.9
1.9
1.9
1.9
1.9
2.0
2.0
85
T.C.
20.9
21.9
21.4
25.2
27.1
23.0
23.1
22.7
25.8
28.0
25.1
24.3
24.0
26.3
28.8
S.C.
20.4
19.8
16.4
16.9
13.8
22.4
21.8
18.7
18.7
14.7
24.5
23.7
21.1
20.5
15.6
KW
1.8
1.8
1.8
1.9
2.0
1.9
1.9
1.9
2.0
2.1
2.1
2.1
2.0
2.1
2.2
95
T.C.
19.1
19.9
18.7
23.1
25.3
21.3
21.6
20.1
23.4
26.3
23.5
23.2
21.5
23.8
27.3
S.C.
18.6
18.9
15.2
16.0
13.1
20.8
20.8
17.6
18.0
14.1
23.0
22.7
20.1
19.9
15.2
KW
1.9
1.9
1.9
2.0
2.1
2.0
2.0
2.0
2.1
2.2
2.2
2.2
2.1
2.2
2.3
105
T.C.
17.4
17.8
16.4
20.1
23.3
19.3
19.8
17.8
20.8
24.1
21.3
21.8
19.1
21.5
24.9
S.C.
16.9
17.1
14.2
14.9
12.2
18.9
19.2
16.2
17.0
13.4
20.8
21.2
18.2
19.1
14.6
KW
2.0
2.0
1.9
2.1
2.2
2.1
2.1
2.1
2.2
2.3
2.3
2.3
2.2
2.3
2.4
115
T.C.
15.6
15.6
14.2
17.2
21.3
17.4
18.0
15.4
18.2
22.0
19.1
20.3
16.7
19.1
22.6
S.C.
15.2
15.2
13.3
13.8
11.2
17.0
17.5
14.8
16.0
12.6
18.7
19.8
16.3
18.3
14.0
KW
2.1
2.1
2.0
2.1
2.3
2.2
2.3
2.1
2.3
2.4
2.4
2.4
2.3
2.4
2.5
125
T.C.
13.9
13.5
11.9
14.2
19.4
15.4
16.2
13.1
15.5
19.8
16.9
18.9
14.4
16.8
20.3
S.C.
13.5
13.4
11.9
12.6
10.3
15.0
15.9
13.1
15.0
11.9
16.5
18.4
14.4
16.8
13.5
KW
2.2
2.1
2.1
2.2
2.4
2.3
2.4
2.2
2.3
2.5
2.5
2.6
2.4
2.5
2.7
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
MV12B
FC/MC24B
1.00
1.00
1.00
MV12B
FC/MC30B
1.00
1.00
1.00
AV24
–
1.00
1.00
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
L*(8,L)C*A12
FC/MC/PC/UC24A
1.00
1.00
1.00
L*(8,L)C*B12
FC/MC/PC/UC24B
1.00
1.00
1.00
L*9C*B12
FC/MC/PC/UC24B
1.00
1.00
1.00
L*(8,L)C*A12
FC/MC/PC/UC30A
1.00
1.00
1.00
L*(8,L)C*B12
FC/MC/PC/UC30B
1.00
1.00
1.00
L*9C*B12
FC/MC/PC/UC30B
1.00
1.00
1.00
L*(8,L)C*A12
HC30
1.00
1.00
1.00