CONNECTING THE WIRES

5. Wires must be trapped between black clamp and brass
terminal.
6. Securely tighten all 7 electrical terminal screws.

4. Hold the base against the wall. Route the wires through the hole below
the terminal block. Position the base for best appearance (to hide any marks
from an old thermostat). Attach the base to the wall with the two screws
provided.

These diagrams are provided for new installations or unreferenced wires.

G

Y

W RH RC

B

O

RH

RC

R

V

5

W

H

4

G

F

HEATING SYSTEMS

COOLING SYSTEMS

All COMMON WIRES MUST BE TAPED OFF.

4- or 5-WIRE WITH ONE TRANSFORMER

5- or 6-WIRE WITH TWO TRANSFORMERS

If a "B" wire in your system is a system common, then  connecting it at the "B"
terminal may cause damage to your system. TAPE IT OFF!

*

If "Y" and "C" are both present, "C" is a common wire. DO NOT USE "C"! TAPE IT OFF!

HEATING / COOLING SYSTEMS

HEATING / COOLING SYSTEMS

JUMPER

PROVIDED

G

Y

W RH RC

B

O

G

F

Y

C*

6

RC

R

V

JUMPER

PROVIDED

G

Y

W RH RC

B

O

RH

B*

RC

R

V

5

G

F

Y

C*

6

W

H

4

JUMPER

PROVIDED

G

Y

W RH RC

B

O

JUMPER

REMOVED

O

RH

B*

V

5

RC

R

G

F

Y

C*

6

W

H

4

O

G

Y

W

RH

RC

B

O

2 WIRE SYSTEM HEAT ONLY

24 VOLT

HEAT

TRANSFORMER

HEAT

120 VAC

JUMPER

G

Y

W

RH

RC

B

O

3 WIRE SYSTEM HEAT ONLY

(3rd WIRE FOR FAN)

24 VOLT

HEAT

TRANSFORMER

FAN

HEAT

120 VAC

JUMPER

G

Y

W

RH

RC

B

O

3 WIRE SYSTEM COOL ONLY

24 VOLT

COOLING

TRANSFORMER

FAN

A/C

COMPRESSOR

120 VAC

JUMPER

G

Y

W

RH

RC

B*

O*

SINGLE STAGE HEAT PUMP SYSTEM

24 VOLT

HEAT

TRANSFORMER

CHANGEOVER

HEAT

CHANGEOVER

COOL

FAN

*"B" OR "O" BUT NEVER BOTH

HEAT

PUMP

120 VAC

ADD

JUMPER

JUMPER

COMPLETING YOUR INSTALLATION

7. See Setup Options to configure jumpers.
8. Install two new Energizer or DURACELL "AA" size alkaline batteries at
this time. For instructions, see BATTERIES/MAINTENANCE.

9.  Install your PSP711CC on its base.
To do this hang the top of the unit by the
tabs on the base, then snap the bottom
of the unit into place. Do not use

unnecessary force. If the body does not snap into place easily, remove the
body, re-hang it from the tabs and try again.
10. Turn the power back on to your heating and/or air conditioning system.
11. Verify that the system and its fan are operating properly. When set to a
high temperature, the heating system should provide warm air after a short
time. Likewise, a cooling system should provide cool air after a short time.
Usually sound from the furnace and air conditioning units can be heard while
they are running. The rush of moving air should be heard within a short time
after either has been started.
12. Your installation is now complete.

N O T E

If you have an electric system and the blower does not operate after

installation, find the electric/gas heat jumper on the back of the body.

Move the jumper to ELEC and perform a HARDWARE RESET.

OPERATING INSTRUCTIONS

G

Y

W

RH

RC

B

O

4 WIRE SYSTEM HEATING AND COOLING

24 VOLT

HEAT/COOL

TRANSFORMER

FAN

A/C

COMPRESSOR

HEAT

120 VAC

JUMPER

G

Y

W

RH

RC

B

O

5 WIRE SYSTEM HEATING AND COOLING

(2 TRANSFORMER SYSTEM)

24 VOLT

HEAT

TRANSFORMER

24 VOLT

COOL

TRANSFORMER

FAN

COOLING

HEAT

120 VAC

120 VAC

JUMPER

REMOVED

The PSP711CC alternately displays the current time and the room

temperature. It also displays the day of the week and the current program
period, MORN, DAY, EVE, or NITE. Set temperatures are indicated in the
right side of the display.

You can make program or setting changes with the thermostat body on

the wall, or conveniently removed from its base plate.

N O T E

Remove sticker from display.

SYSTEM MODES:

The Mode switch has three positions HEAT, OFF, and COOL. In the winter,

set the system switch to HEAT to control your heating system. In the
summer, set the switch to COOL to control your air conditioner. In spring and
fall or when the windows are open, you can set the switch OFF.

UP/DOWN/CHANGE ARROW KEYS:

There are two arrow keys just right of the unit’s display. They are used to

adjust set temperatures and change other settings.

Содержание LUXPRO PSP711CC series

Страница 1: ...ons mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise On new installations follow the guidelines listed below 1 Locate the thermostat on an inside wall about 5 ft 1 5m above the floor and in a room that is used often 2 Do not install it where there are unusual heating conditions such as in direct sunlight near a lamp television radiator register ...

Страница 2: ...bs on the base then snap the bottom of the unit into place Do not use unnecessary force If the body does not snap into place easily remove the body re hang it from the tabs and try again 10 Turn the power back on to your heating and or air conditioning system 11 Verify that the system and its fan are operating properly When set to a high temperature the heating system should provide warm air after...

Страница 3: ...ps 3 10 described in WEEKDAY PROGRAMMING to program Saturday and Sunday START AT PROGRAM MORN SU AM HEAT SET 6 0070 CLEAN AIR CYCLE The CLEAN AIR CYCLE insures that the fan runs for at least the specified duration each hour to circulate and filter the air in your home Hourly fan run time may be specified from 9 to 60 minutes per hour 60 ON or continuous run The default minimum run time is 15 minut...

Страница 4: ...nace and air conditioner OFF 2 To access your units batteries remove the unit from the wall by pressing up on the thumb latch at the bottom of thermostat and swinging the body up and away 3 Remove the used batteries 4 Install two new Energizer or DURACELL AA size alkaline batteries in the battery compartment Observe the polarity marking shown in the compartment 5 Hang the top of the unit by the ta...

Отзывы: