9. Error messages – What do I do when...?
...the battery symbol appears on the display?
Change the batteries. (
→
chapter 8.2)
...nothing appears on the display?
Ensure that the batteries have been placed in the correct orientation and the battery cable has been
connected to the control circuit board.
Check if the batteries have sufficient charge. Replace batteries if necessary. (
→
chapter 8.2)
…the value on the display does not change, or only moves very slowly?
Free the turbine in the measuring chamber of foreign objects.
…the display shows too much or too little?
Check that the permissible flow rate and media specifications are complied with.
Calibrate the flow meter (
→
chapter 7.4)
...the illumination no longer works?
Change the batteries (
→
chapter 8.2)
10. Waste disposal
The device is to be emptied completely and the liquids properly disposed of in case it is taken out of
service. In case the device is put out of service permanently then it has to be disposed of properly:
►
Return old metal for recycling.
►
Return plastic parts for recycling.
►
Return electronic waste for recycling.
NOTICE
The water legal regulations are to be followed.
10.1 Return of batteries
Batteries must not be disposed of with the domestic waste. Batteries can be returned free of charge
via a suitable collecting point or to the dispatch stores. Consumers are legally obliged to return used
batteries.
Batteries that contain harmful substances are marked with a crossed out dustbin (see above) and the
chemical symbol (Cd, Hg or Pb) of the heavy metal that is decisive for the classification as containing
harmful substances:
1. “Cd” stands for cadmium.
2. “Pb” stands for lead.
3. “Hg” stands for mercury.