5.5 Rotating the display
The display of the flow meter TR3 (1) can be
mounted both vertically as well as horizontally
in order to allow the meter to be read off
comfortably (
→
Fig. 5).
To turn the display, the four screws (2) on the
top side are loosened and the display is pulled
upwards. The display can now be replaced in any
desired orientation.
The rubber shock protector (3) is not to be rotated
along with the display.
The battery housing (4) may need to be placed on
the other side (5) of the meter housing to prevent
the battery housing and battery connector (6)
from colliding.
The battery cable needs to be laid such that it
is not pinched between the reed switch and the
housing.
Fig. 5
6. Operation
3
All connections and fittings are properly
tightened.
The flow meter TR3 is operated using three keys
(
→
Fig. 6): "Reset" (2), "Mode" (3) and "Light" (1).
Information is shown on the LCD display (4) with a
permanently visible display.
The flow meter is set by the manufacturer with
unit of measurement “Litres” and calibration
factor “1.000”. The accuracy of the display
can be increased through calibration, and the
unit of measurement can also be changed (
→
chapter 7). After installation, the meter is ready to
measure dispensations without requiring further
configuration.
Fig. 6