background image

Exploded Views & Parts Lists

Exploded View - LI20-FP*-****-*** Bolted Plastic

190 OPTIONAL

 381 

 382 

 383 

 371 

 353 

 352 

 351 

 10 

 354 

 361 

 362 

 20 

 30 

 40 

 61 

 62 

 70 

 80 

 90 

 100 

 110 

 120 

 130 

 140 

 150 

 160 

 170 

 180 

 220 

 230 

 240 

 250 

 260 

 270 

 280 

 290 

 300 

 311 

 312 

 320 

 210 

 50 

 372 

 190 

P h o n e :   ( 5 8 5 )   4 2 6 - 0 9 9 0  

 www.lutzjescoamerica.com

 

 Fax: (585) 426-4025

19

Operation & Maint

enance Ins

tructions 

 

AODD: 2” Air Operat

ed Double Diaphragm Pum

p

Содержание AIRTRAN LI20-FP Series

Страница 1: ...A measured step forward TM AIRTRAN 2 Air Operated Double Diaphragm Pump...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK P h o n e 5 8 5 4 2 6 0 9 9 0 www lutzjescoamerica com Fax 585 426 4025 2 Operation Maintenance Instructions AODD 2 Air Operated Double Diaphragm Pump...

Страница 3: ...12 Repair and Assembly 13 Pump Wet End Removal 13 Pump Wet End Assembly 14 Repair and Assembly 15 Air Valve Removal 15 Air Valve Assembly 16 Repair and Assembly 17 Pilot Valve Removal 17 Torque Specif...

Страница 4: ...y the materials in contact with the fluid being pumped Consult a chemical resistance guide for chemical compatibility and a more precise safe temperature limit Always use minimum air pressure when pum...

Страница 5: ...ler Grounding Lug Installed Note Equipment must be grounded to acheive ATEX rating It is recommended to configure the pump with a grounding lug option for ATEX applications SPECIAL OPTION OTHER 0 Stan...

Страница 6: ...e outward to the left Since both the left diaphragm and the right diaphragm are connected via a dia phragm rod when the left diaphragm moves to the left the right diaphragm through the action of the d...

Страница 7: ...6 446 31 7 805 13 7 349 12 2 310 1 9 49 7 6 194 6 0 153 4 0 101 14 2 360 16 7 423 0 6 14 8 2 208 9 2 234 Dimensions in inches mm P h o n e 5 8 5 4 2 6 0 9 9 0 www lutzjescoamerica com Fax 585 426 402...

Страница 8: ...O Weight Polypropylene 56 lbs 25 kg Weight PVDF 84 lbs 38 kg Air Inlet 3 4 FNPT Liquid Inlet 2 ANSI DIN FLANGE Liquid Outlet 2 ANSI DIN FLANGE Height 31 7 805 mm Width 23 6 600 mm Depth 12 2 310 mm 0...

Страница 9: ...ragm failure this will reduce or eliminate the pos sibility of liquid discharging through the exhaust onto the ground Location Ensure that the pump is installed in an accessible location in order to f...

Страница 10: ...ustration is a generic representation of an air operated double diaphragm pump P h o n e 5 8 5 4 2 6 0 9 9 0 www lutzjescoamerica com Fax 585 426 4025 10 Operation Maintenance Instructions AODD 2 Air...

Страница 11: ...essive Debris stuck in valves Excessive wear of check valves Air leak on suction side with suction lift Pump Cycles with Closed Discharge Valve Debris stuck in check valve Excessive wear of check valv...

Страница 12: ...partially closing a liquid suction valve restrict the suction line and may cause damage to the diaphragms Suction strainers may be employed to reduce or eliminate larger solids but routine maintenance...

Страница 13: ...ight Hex Head Cap Screws and Lock Washers sixteen Washers and eight Hex Nuts from the Dishcharge Manifold STEP 2 Remove the Discharge Manifold STEP 3 Remove the O Ring Valve Seat and Ball from the Dis...

Страница 14: ...ower four bolts are inserted from the center STEP 8 Remove both Outer Chambers and Power Rings from the Intermediate Note the Lock Washers are installed on the Power Rings which should be on the Inter...

Страница 15: ...ash ers Flat Washers and Hex Nuts rear STEP 2 Remove the main Air Valve Assembly from the pump STEP 3 Remove the Air Valve Gasket from the main Air Valve Assembly STEP 4 Remove the Shuttle Plate from...

Страница 16: ...ly they will be unable to rotate Insert the spool larger chamber side first the spool s longer piston with the boss is to be on the plug side ensure O Ring is installed and then the air valve end plug...

Страница 17: ...ure that the air and fluid lines are closed and disconnected While wearing personal protective equipment flush and drain process liquid from the pump WARNING Maintenance must not be performed when a h...

Страница 18: ...rdering information Torque Specification Chart RECOMMENDED TORQUE SPECIFICATIONS 2 Pumps Chamber Bolts 20 ft lbs 27 1 N m Air Valve Bolts 40 in lbs 4 52 N m Diaphragm Plates 372 in lbs 42 0 N m Manifo...

Страница 19: ...352 351 10 354 361 362 20 30 40 61 62 70 80 90 100 110 120 130 140 150 160 170 180 220 230 240 250 260 270 280 290 300 311 312 320 210 50 372 190 P h o n e 5 8 5 4 2 6 0 9 9 0 www lutzjescoamerica com...

Страница 20: ...ypropylene 110 Pilot Sleeve 4 ALL MODELS 11919 16 Urethane 120 END SPACER Pilot Sleeve 2 ALL MODELS 10206 40 Polypropylene 130 O RING End Spacer 2 ALL MODELS 11919 11 Nitrile 140 LIP SEAL Diaphragm Ro...

Страница 21: ...HEX 1 2 13 36 ALL MODELS NON PTFE COATED 12604 26 Stainless Steel 371 WASHER LOCK 1 4 6 ALL MODELS NON PTFE COATED 12350 26 Stainless Steel 372 WASHER SPLIT LOCK 1 4 36 ALL MODELS NON PTFE COATED 123...

Страница 22: ...r to EPDM Has excellent abrasion resistance Temperature range 40 F to 225 F 40C to 107C FKM is an elastomer with good corrosion resistance to a wide variety of chemicals Similar in chemical resistance...

Страница 23: ...THIS PAGE INTENTIONALLY LEFT BLANK P h o n e 5 8 5 4 2 6 0 9 9 0 www lutzjescoamerica com Fax 585 426 4025 23 Operation Maintenance Instructions AODD 2 Air Operated Double Diaphragm Pump...

Страница 24: ...complete chemical feed system we provide you with the appro priate Total Fluid Management solution Please contact us for more information Lutz JESCO Corp 55 Bermar Park Rochester NY 14624 Phone 585 42...

Отзывы: