background image

Setup

Wired

RF

Communication

Repeater Status

1

4

2

 M

Power Repeater Link

CO
M

9 V

1

N / 
C

MU
X

MU
X

2

3

4

Add

Test

USB

Integrate

Program / Integrate

RS232

Ethernet

Main Repeater

LUTRON

Room Set

80°

75°

70°

65°

60°

eco

Setup

Wired

RF

Communication

Repeater Status

1

4

2

 M

Power Repeater Link

CO
M

9 V

1

N / 
C

MU
X

MU
X

2

3

4

Add

Test

Auxiliary Repeater

LUTRON

Room Set

80°

75°

70°

65°

60°

eco

Setup

Wired

RF

Communication

Repeater Status

1

4

2

 M

Power Repeater Link

CO
M

9 V

1

N / 
C

MU
X

MU
X

2

3

4

Add

Test

Hybrid Repeater

Lutron

®

 

|

 5

www.lutron.com

product specifications

06.28.12

369539b

Lutron

R

 Comfort Controls

TouchPRO Wireless

TM

 Thermostat

Setup

Wired

RF

Communication

Repeater Status

1

4

2

 M

Power Repeater Link

CO
M

9 V

1

N / 
C

MU
X

MU
X

2

3

4

Add

Test

USB

Integrate

Program / Integrate

RS232

Ethernet

Main Repeater

LUTRON

Room Set

80°

75°

70°

65°

60°

eco

Setup

Wired

RF

Communication

Repeater Status

1

4

2

 M

Power Repeater Link

CO
M

9 V

1

N / 
C

MU
X

MU
X

2

3

4

Add

Test

Auxiliary Repeater

LUTRON

Room Set

80°

75°

70°

65°

60°

eco

Setup

Wired

RF

Communication

Repeater Status

1

4

2

 M

Power Repeater Link

CO
M

9 V

1

N / 
C

MU
X

MU
X

2

3

4

Add

Test

Hybrid Repeater

Wireless Router 

(not sold by Lutron)

Wireless Router 

(not sold by Lutron)

RF Link  

60 ft (18 m) 

Maximum

30 ft (9 m) 

Maximum

30 ft (9 m) 

Maximum

30 ft (9 m) 

Maximum

Main Repeater

Processor

Auxiliary Repeater

Hybrid Repeater

System Examples

seeTemp

T

 

Wall Display

seeTemp

T

 

Wall Display

Dynamic 

Keypad (RF)

Dynamic 

Keypad (wired)

TouchPRO 

Wireless

T

 

Thermostat

TouchPRO 

Wireless

T

 

Thermostat

Ethernet 

Connection

Ethernet 

Connection

24 V

-  

Input

nput

Lutron

R

 Home 

 

mobile device 

application

Lutron

R

 Home 

 

mobile device 

application

HVAC Equipment 

(not sold by Lutron)

HVAC Equipment 

(not sold by Lutron)

RadioRA

R

 2

HomeWorks

R

 QS

Содержание TouchPRO Wireless LR-HWLV-HVAC

Страница 1: ...zes LutronR Clear ConnectR technology The TouchPRO WirelessT Thermostat installs like a conventional thermostat and when used with a seeTempT Wall Display it puts temperature control and measurement where it makes sense In a RadioRAR 2 or HomeWorksR QS system the TouchPRO WirelessT Thermostat allows the ability to adjust heating and cooling systems any time of the day even from your mobile device ...

Страница 2: ...Hz ESD Protection Tested to withstand electrostatic discharge without damage or memory loss in accordance with IEC 61000 4 2 Surge Protection Tested to withstand surge voltages without damage or loss of operation in accordance with IEEE C62 41 1991 Recommended Practice on Surge Voltages in Low Voltage AC Power Circuits Power Failure Power failure memory should power be interrupted the TouchPRO Wir...

Страница 3: ...O WirelessT Thermostat from multiple locations Pressing the eco button saves energy by trimming the temperature a programmed amount Default is 2 F 1 C 120 V wiring requires hot and neutral wiring 24 V wiring requires 24 V and common wiring from HVAC equipment transformer or other 24 V IEC PELV NECR Class 2 transformer Design Features Lutron System Features 7 day programmable schedule Select altern...

Страница 4: ...ual Fuel Systems Yes Geothermal Heat Pump Yes Heat Pump with Auxiliary Electric Emergency Heat Yes Typical Variable Speed Fan Equipment Controlled Yes Multi Zone Systems Controllable Dampers Yes Requires a separate Zone Controller not sold by Lutron In Floor Radiant Heat Yes Line Voltage Electric Baseboard No Mili Volt System No Proprietary Digital Control systems No Variable Speed Fan Independent...

Страница 5: ...RS232 Ethernet Main Repeater LUTRON Room Set 80 75 70 65 60 eco Setup Wired RF Communication Repeater Status 1 3 4 2 M Power Repeater Link COM 9 V 1 N C MUX MUX 2 3 4 Add Test Auxiliary Repeater LUTRON Room Set 80 75 70 65 60 eco Setup Wired RF Communication Repeater Status 1 3 4 2 M Power Repeater Link COM 9 V 1 N C MUX MUX 2 3 4 Add Test Hybrid Repeater Wireless Router not sold by Lutron Wireles...

Страница 6: ...tronR Comfort Controls TouchPRO WirelessR Thermostat Dimensions All dimensions are shown as unless otherwise noted in mm Front View Side View 69 16 167 17 16 37 415 16 125 Mounting and Parts Identification Wall Anchors TouchPRO WirelessT Thermostat Wire Hole Mounting Screws Mounting Holes ...

Страница 7: ...on can be programmed to cycle through the replacement schedules for the filter pad UV lamp and humidity pad Current Time Current Inside Temperature Temperature Setting Fan Setting Button Press to select fan operation On Fan is always on Auto Fan runs only when the heating or cooling system is on System Setting Button Press to select system type Heat Thermostat only controls the heating system Cool...

Страница 8: ...Rc Cooling power Connect to secondary side of cooling system transformer C Required common wire from secondary side of cooling transformer if 2 transformers W 1st stage heat relay W2 2nd stage heat relay Y 1st stage compressor contactor Y2 2nd stage compressor contactor G Fan relay L Heat pump reset powered continuously when system is set to Em Heat system monitor when set to Heat Cool or Off O B ...

Страница 9: ...c R and Rc joined by jumper R Series 20 valve terminal R W Series 20 valve terminal B Y Series 20 valve terminal W C 24 V common S1 S2 Optional remote sensor Rc Power R R and Rc joined by jumper Y Compressor contactor G Fan relay C 24 V common S1 S2 Optional remote sensor Y2 Compressor contactor 2 W2 Heat 2 relay Rc Power R R and Rc joined by jumper W Heat relay 1 Y Compressor contactor 1 G Fan re...

Страница 10: ... 1 G Fan relay C 24 V common S1 S2 Optional remote sensor L Equipment monitor E Aux Auxiliary heat relay heat 2 Rc Power R R and Rc joined by jumper O B Changeover valve Y Compressor contactor G Fan relay C 24 V common S1 S2 Optional remote sensor Y2 Compressor contactor 2 L Equipment monitor E Aux Auxiliary heat relay heat 2 Rc Power R R and Rc joined by jumper O B Changeover valve Y Compressor c...

Страница 11: ... Controls TouchPRO WirelessTM Thermostat THP9045 Wiring Module The THP9045 wiring module included with the TouchPRO WirelessR Thermostat is used in retrofit applications where no common wire is available between the thermostat and the HVAC equipment It is wired between the HVAC equipment and the TouchPRO and is mounted on or near the HVAC equipment ...

Страница 12: ... RC R O B Y G C RC R W Y G C Y2 W2 K S1 S2 EQUIPMENT THERMOSTAT Rc K C W O B Rc Y G C W O B Honeywell THP9045A HVAC Equipment Power Compressor Contactor Fan Relay 24 V Common Heat Relay 1H 1C System Cool Only System Y2 L E AUX K S1 S2 RC R O B Y G C RC R W Y G C Y2 W2 K S1 S2 EQUIPMENT THERMOSTAT Rc K C W O B Rc Y G C W O B Honeywell THP9045A HVAC Equipment Power Compressor Contactor 1 Compressor ...

Страница 13: ...UX K S1 S2 RC R O B Y G C RC R W Y G C Y2 W2 K S1 S2 EQUIPMENT THERMOSTAT Rc K C W O B Rc Y G C W O B Honeywell THP9045A HVAC Equipment Power cooling transformer Compressor Contactor Fan Relay 24 V Common Cool Only System Y2 L E AUX K S1 S2 RC R O B Y G C RC R W Y G C Y2 W2 K S1 S2 EQUIPMENT THERMOSTAT Rc K C W O B Rc Y G C W O B Honeywell THP9045A HVAC Equipment Power cooling transformer Power he...

Страница 14: ...W2 K S1 S2 EQUIPMENT THERMOSTAT Rc K C W O B Rc Y G C W O B Honeywell THP9045A HVAC Equipment Power cooling transformer Power heating transformer Compressor Contactor 1 Compressor Contactor 2 Fan Relay Heat Relay 1 Heat Relay 2 24 V Common cooling transformer 2H 2C System 2 transformers Note Remove jumper between RC and R on thermostat 14 Lutron 24 7 Technical Support 800 523 9466 product specific...

Страница 15: ...2 L E AUX K S1 S2 RC R O B Y G C RC R W Y G C Y2 W2 K S1 S2 EQUIPMENT THERMOSTAT Rc K C W O B Rc Y G C W O B Honeywell THP9045A HVAC Equipment Power Compressor Contactor Fan Relay 24 V Common Changeover Valve 1H 1C Heat Pump no auxiliary heat 2H 2C Heat Pump no auxiliary heat Y2 L E AUX K S1 S2 RC R O B Y G C RC R W Y G C Y2 W2 K S1 S2 EQUIPMENT THERMOSTAT Rc K C W O B Rc Y G C W O B Honeywell THP...

Страница 16: ... L E AUX K S1 S2 RC R O B Y G C RC R W Y G C Y2 W2 K S1 S2 EQUIPMENT THERMOSTAT Rc K C W O B Rc Y G C W O B Honeywell THP9045A HVAC Equipment Power Compressor Contactor 1 Compressor Contactor 2 Fan Relay 24 V Common Changeover Valve 2H 2C Heat Pump no auxiliary heat Y2 L E AUX K S1 S2 RC R O B Y G C RC R W Y G C Y2 W2 K S1 S2 EQUIPMENT THERMOSTAT Rc K C W O B Rc Y G C W O B Honeywell THP9045A HVAC...

Отзывы: