Description

2 conductors / #22-24 AWG

3 conductors (2 shielded, 1 common) 
#24 AWG Belden

®

wire model #1883A

3 conductors:

2 / #18-22 AWG (24 VAC power supply)
1 / #18-22 AWG (earth ground)

6 conductors:

2 / #16 AWG (24 VAC power supply)
1 / #18 AWG (earth ground)
3 #22 AWG sh 1 #24 AWG  

common (comm link)

(

Lutron

wire part no. SV-CBL-MDU-250)

3 conductors #22 AWG 

Lutron

model # SV-IR-EXT-10

Maximum Length

Control to MDU: 250 ft.(76 m)

4000 ft. (1333 m) per system
1000 ft. (333 m) from MDU to MDU

Transformer to MDU:

#18 AWG - 150 ft. (46 m)
#20 AWG - 100 ft. (31 m)
#22 AWG -   60 ft. (18 m)

MDU to 

Sivoia

power panel:

200 ft. (61 m)

50 ft. (15 m) per system - 
total of 5 SV-IR-EXT-10, 10 ft.
(3 m) each

1 2 3 4

5 6 7 8

Cntrl 1

Cntrl 

2

Ground

AC

AC

Common

MUX

MUX

B

Do not connect if there is only one MDU in the system.

If there are

multiple MDU's in the  system,the MDU's must be wired together. Connect the
MUX, Common, and MUX terminals of each MDU together in a daisy chain or
homerun configuration.

To a 

Sivoia

wall mounted keypad, or a 

Sivoia

interface such as the SV-CCI-GRP

or the SV-GRXI. The CNTRL1 and CNTRL2 wires are

polarity sensitive

.

Wire to a 

Sivoia

100VA plug-in transformer, junction box mount transformer,

or a 

Sivoia

power panel. Each MDU must be EARTH grounded. One 

Sivoia

transformer can power

ONLY ONE MDU

regardless of drapery size.

Control

Comm

Link

Power

Supply

IR Connector

System Wiring – Single MDU

6

9

C O N N E C T I N G   W I R E S   T O   T H E   M D U   T E R M I N A L   B L O C K

The terminal block located at the bottom of the MDU is the wire 
connection point for: power, communication, keypads, and interfaces.

1.

Remove terminal block cover by pressing in on the cover and then
pulling downward.

2.

Grasp terminal block and pull down to separate from connecting block.

3.

Connect wires to the terminal block according to the diagram below.

4.

Replace the terminal block and the terminal block cover.

Wire Type

Control

A

Comm Link

B

Power Wires

C

Comm & Power

D

B   &

C   combined 

in one cable

SV-IR 

E

Extension Cable

A

E

B

C

Sivoia

®

Drapery

Содержание SIVOIA

Страница 1: ...allation pg 6 7 5 Hanging Drapery Fabric pg 8 6 System Wiring pg 9 10 7 Configuring the MDU pg 11 12 8 Infrared Control pg 13 9 Troubleshooting pg 14 10 Warranty pg 15 16 1 Wallstation Control Transformer SV IR Infrared Receiver Module and Infrared Handheld Transmitter not included Wallstation Control Transformer SV IR Infrared Receiver Module Infrared Handheld Transmitter Drapery System Sivoia ...

Страница 2: ...ONE WAY DRAW SYSTEM RIGHT DRAW SHOWN OR ONE WAY DRAW SYSTEM LEFT DRAW SHOWN 2 OR SPLIT DRAW SYSTEM Carton Contents 1 Sivoia Drapery ...

Страница 3: ...evel Pliers Tape Measure Wire Cutter Wire Stripper 3 Carton Contents 1 Tools Required 2 WALL MOUNT BRACKETS WITH CAM LOCK quantity depends on system width ONE HOOK EYE split dra w only AUXILIARY CARRIERS quantity depends on system width CEILING MOUNT CAM LOCKS quantity depends on system width Sivoia Drapery ...

Страница 4: ...ach bracket must be mounted along a straight and level line The drapery track must be straight and level to operate properly When the wall brackets are securely mounted install the track to the brackets using the cam locks SEE ILLUSTRATIONS BELOW FOR CAM LOCK OPERATION Side Elevation View CAM LEVER 4 Wall Mounting the Drapery Track 3 Window Wall Side Level Line track Top View bracket 3 5 6 in Adju...

Страница 5: ...of the ceiling is not straight and level use shims between the cam lock bracket and the ceiling to compensate for the irregularities To mount the track to the brackets position all the cam lock lever arms to the unlocked position see unlocked diagram below Position the track up against the cam lock brackets and rotate the cam lock arm to the locked position CAM LEVER Orient each cam lever in the p...

Страница 6: ...ug on the motor side of the track Insert or remove auxiliary carriers through the square hole in the track until the proper number of carriers are installed Replace plastic square plug by pushing it up into the square home until it snaps into place 3 2 1 Motor Housing hooks for last two 2 drapery hooks Master Carrier 6 Carrier Installation Left and Right Draw Systems 4 First two 2 drapery hooks sh...

Страница 7: ...ndcap See diagram below Idle end hook eye Remove idle end cover 2 Carrier Installation Split Draw Systems 4 7 TO ADD OR REMOVE CARRIERS Split Drive Systems Follow the directions on page 6 for motor side plug removal and installation of the auxiliary carriers Remove screw that retains the idle end cover Remove idle and hook eye Insert or remove auxiliary carriers through the square hole in the idle...

Страница 8: ...stem performance a drapery hook setting of 1 2 in should be used This allows the system to operate with minimal noise DRAPERY FABRIC RETURN Hanging Drapery Fabric 5 8 4 0 6 5 in depends on wall mount bracket extension 50 in Sivoia Drapery ...

Страница 9: ...f each MDU together in a daisy chain or homerun configuration To a Sivoia wall mounted keypad or a Sivoia interface such as the SV CCI GRP or the SV GRXI The CNTRL1 and CNTRL2 wires are polarity sensitive Wire to a Sivoia 100VA plug in transformer junction box mount transformer or a Sivoia power panel Each MDU must be EARTH grounded One Sivoia transformer can power ONLY ONE MDU regardless of drape...

Страница 10: ...iple MDUs 10 Description 2 conductors 22 24 AWG 3 conductors 2 shielded 1 common 24 AWG Belden wire model 1883A 3 conductors 2 18 22 AWG 24 VAC power supply 1 18 22 AWG earth ground 6 conductors 2 16 AWG 24 VAC power supply 1 18 AWG earth ground 3 22 AWG shielded 1 24 AWG common comm link Lutron wire part no SV CBL MDU 250 3 conductors 22 AWG Lutron model SV IR EXT 10 Maximum Length Control to MDU...

Страница 11: ... continue with the setup codes for multiple MDU systems on the next page 11 7 Configuring the Motor Drive Unit MDU Steps Step 1 Step 2 Set Press the Set button to save the current position as the Open Limit The display will read and blink for 4 seconds then go blank Press the Set Button to save the current position as the Close Limit The display will read and blink for 4 seconds then go blank Mode...

Страница 12: ...ion Determines which MDU s in the system will respond to a Group keypad or Group interface control that is wired to the MDU being setup It is not necessary to change the control station setting of an MDU that does not have any keypads or interfaces wired to it There are two types of Sivoia keypads and interfaces group and individual types The table to the left describes how a group type controls a...

Страница 13: ...ering for the shade system To extend the IR receiver mounting range add up to five 5 SV IR EXT 10 extension cables 10 ft 3 m each Note To control an individual drapery with an IR transmitter the SV IR must be connected to that MDU If there is a Group Subgroup of MDU s with the same Room IR Address see page 11 the SV IR need only be con nected to one of those MDU s to control the entire Group Subgr...

Страница 14: ...block is connected securely and wired correctly 3 If using wall keypad check that wall keypad has been wired correctly 4 If using IR remote confirm that SV IR infrared receiver is wired to MDU correctly and is not obstructed 5 If using IR remote check transmitter batteries Draperies do not move together in a group 1 Confirm that all MDUs are wired correctly including power and Comm Link 2 Confirm ...

Страница 15: ...s 3 4 and 5 after the date of shipment 50 For years 6 7 and 8 after the date of shipment 25 WHAT THIS WARRANTY DOES NOT COVER 1 Damage or improper operation determined by Vimco to be due to normal wear and tear or to abuse misuse or accident such as a Use of incorrect line voltages b Use of incorrect fuses or circuit breakers c Failure to follow operating instructions provided by VIMCO d Unauthori...

Страница 16: ...SION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU This product may be covered under one or more of the following U S Patents 5 671 387 6 313 588 6 346 781 DES 370 663 DES 378 814 DES 437 585 DES 450 043 and DES 462 332 and corresponding foreign patents U S and foreign patents pending Lutron the sunburst logo and Sivoia are registere...

Отзывы: