Lutron Electronics PCO-350 Скачать руководство пользователя страница 4

Zero

Build in zero button for offsetting
the zero value

Operating 

0 to 50  .

Temperature
Operating 

Less than 80% R.H.

Humidity
Power Supply

DC 1.5 V battery ( UM4/AAA ) x 4 PCs.

Power Current Approx. DC 4.0 mA
Weight

194 g/ 0.43 LB.

Dimension

180 x 40 x 40 mm (7.1" x 1.6" x 1.6")

Accessories

Instruction manual......................1 PC

Included

Soft carrying case ( CA-52A ).......1 PC

2-2 Electrical Specifications  (23± 5  )

CO ( Carbon dioxide )

Range

0 to 1,000 PPM

CO

Resolution

1 PPM

 * Carbon 

Accuracy

±  ( 5% + 2 PPM )

monoxide 

Response 

< 30 seconds

time *

Repeatability < 2%

Zero drift in

< 5 PPM

long term

Sensitivity

< 5% per year

drift

* The response time value is specified to reach

the 90% reading value.

Temperature

Range

0   to 50  ,32   to 122  .

Temperature Resolution

0.1 degree.

Accuracy

±   0.8 

 

± 1.5  .

@ Above specification tests under the environment RF Field Strength less than 3

V/M & frequency less than 30 MHz only.

2

Содержание PCO-350

Страница 1: ...o the field of precision measurement Although this METER is a complex and delicate instrument its durable structure will allow many years of use if proper operating t e c h n i q u e s a r e developed...

Страница 2: ...Sensing Head 3 3 2 Power Button 3 3 3 Hold Button 3 3 4 Alarm Button 3 3 5 LCD Display 3 3 6 Battery Compartment Cover 3 4 MEASURING PROCEDURE 4 4 1 CO measurement 4 4 2 Data hold 4 4 3 CO Alarm sett...

Страница 3: ...ures Auto shut off function to prolong the battery life Operates from DC 1 5V UM4 AAA x 4 PCs batteries Durable and compact ABS plastic housing 2 SPECIFICATIONS 2 1 General Specifications Circuit Cust...

Страница 4: ...ing case CA 52A 1 PC 2 2 Electrical Specifications 23 5 CO Carbon dioxide Range 0 to 1 000 PPM CO Resolution 1 PPM Carbon Accuracy 5 2 PPM monoxide Response 30 seconds time Repeatability 2 Zero drift...

Страница 5: ...3 FRONT PANEL DESCRIPTION Fig 1 3 1 CO Sensing Head 3 2 Power Button 3 3 Hold Button 3 4 Alarm Button 3 5 LCD Display 3 6 Battery Compartment Cover 3...

Страница 6: ...3 3 Fig 1 momentarily to hold the measured value The LCD will show a HOLD symbol 2 Press the Hold Button once again to release the data hold function 4 3 CO Alarm setting Press the Alarm Button 3 4 Fi...

Страница 7: ...the Temp unit or is presented on the Display then release the Hold Button the Temp unit will change From to or to with default 4 6 Zero adjustment Put the meter into the clean air environment not cont...

Страница 8: ...s Environmental Protection Agency 35 PPM Max exposure time 1 hour United States Environmental Protection Agency 50 PPM Max exposure time 8 hour OSHA 100 PPM Max exposure 100 minutes Circulation air UL...

Отзывы: