1. FEATURES

* Two function : CO ( Carbon monoxide ), Temperature.
* CO range : 0 to 1,000 PPM x 1 PPM.
* Temperature. : 0 to 50  , /  

℃ ℃ ℉

* CO measurement with fast response time.
* High repeatability and high accuracy.
* Pen type, easy to carryout and operation.
* CO function with alarm setting.
* Data hold function for freezing the desired value

on display.

* Microprocessor circuit assures maximum possible

accuracy, provides special functions and features.

* Auto shut off function to prolong the battery life.
* Operates from DC 1.5V ( UM4/AAA ) x 4 PCs batteries.
* Durable and compact ABS-plastic housing.

2. SPECIFICATIONS

2-1 General Specifications

Circuit

Custom one-chip of microprocessor LSI
circuit.

Display

LCD size : 28 mm x 19 mm.

Measurement

CO( Carbon dioxide ),
Temperature

Unit

CO

PPM

Temp.

,  

℃ ℉

Sensor Type

CO

Electrochemical

Temperature Thermistor

Temperature

Automatic temp. compensation for

Compensation CO measurement.
Alarm Setting

For CO measurement only.

Data Hold

Freeze the display reading.

Sampling Time Approx. 1 second.
Power off

Auto shut off saves battery life.

1

Содержание PCO-350

Страница 1: ...o the field of precision measurement Although this METER is a complex and delicate instrument its durable structure will allow many years of use if proper operating t e c h n i q u e s a r e developed...

Страница 2: ...Sensing Head 3 3 2 Power Button 3 3 3 Hold Button 3 3 4 Alarm Button 3 3 5 LCD Display 3 3 6 Battery Compartment Cover 3 4 MEASURING PROCEDURE 4 4 1 CO measurement 4 4 2 Data hold 4 4 3 CO Alarm sett...

Страница 3: ...ures Auto shut off function to prolong the battery life Operates from DC 1 5V UM4 AAA x 4 PCs batteries Durable and compact ABS plastic housing 2 SPECIFICATIONS 2 1 General Specifications Circuit Cust...

Страница 4: ...ing case CA 52A 1 PC 2 2 Electrical Specifications 23 5 CO Carbon dioxide Range 0 to 1 000 PPM CO Resolution 1 PPM Carbon Accuracy 5 2 PPM monoxide Response 30 seconds time Repeatability 2 Zero drift...

Страница 5: ...3 FRONT PANEL DESCRIPTION Fig 1 3 1 CO Sensing Head 3 2 Power Button 3 3 Hold Button 3 4 Alarm Button 3 5 LCD Display 3 6 Battery Compartment Cover 3...

Страница 6: ...3 3 Fig 1 momentarily to hold the measured value The LCD will show a HOLD symbol 2 Press the Hold Button once again to release the data hold function 4 3 CO Alarm setting Press the Alarm Button 3 4 Fi...

Страница 7: ...the Temp unit or is presented on the Display then release the Hold Button the Temp unit will change From to or to with default 4 6 Zero adjustment Put the meter into the clean air environment not cont...

Страница 8: ...s Environmental Protection Agency 35 PPM Max exposure time 1 hour United States Environmental Protection Agency 50 PPM Max exposure time 8 hour OSHA 100 PPM Max exposure 100 minutes Circulation air UL...