2)Slide the " Battery Cover " ( 3-7, Fig. 1 ) away from the

instrument and remove the battery.

3)Replace with 9V battery ( Alkaline or Heavy duty type )

and reinstate the cover.

4)Make sure the battery cover is secured after changing the

battery.

9. OPTIONAL PROBES and

     ACCESSORIES

Probe sensing head 

* After the probe ( MS-71P ) is use for a

with inner filter,

long time, the inner filter will dirty and

Model : MS71HEAD

need to make the replacement.

* It is the parts include the Probe head

with the inner filter, one set.

Type K

* Measure Rage : -40   to 250  ,

Thermocouple

-40   to 482  .

Probe

* Ultra fast response naked-bead

Model: TP-01 

thermocouple, general purpose

application.

Type K

* Measure Range : -50   to 900  ,

Thermocouple

-50   to 1650  .

Probe

* Dimension: 10 cm tube, 8 mm Dia.

Model: TP-02A

Type K

* Measure Range :-50   to 1200  ,

Thermocouple

-50  to 2200  .

Probe

* Size: Temp. sensing head - 15 mm

Model: TP-03

Dia. Probe length: 120 mm.

Type K

* Measure Range : -50   to 400  ,

Thermocouple

-50   to 752  .

Probe

* Dimension: 10 cm tube, 8 mm Dia.

Model: TP-04

RS232 cable

RS232 cable for connecting between

UPCB-02

the meter & the computer ( COM port ).

USB cable

USB cable for connecting between

USB-01

the meter & the computer ( USB port ).

SOFTWARE

Windows version application software

SW-U801-WIN

applies as the performance of data

logging system & data recorder...

14

Содержание MS-7011

Страница 1: ...x and delicate instrument its durable structure developed Please read the following instructions carefully and always keep this manual within easy reach OPERATION MANUAL Heavy duty probe Dew point Typ...

Страница 2: ...6 3 11 Stand 6 3 12 Probe Plug 6 3 13 Probe handle 6 3 14 Probe main body 6 3 15 Sensing head with inner filter 6 3 16 Protection cover for Sensing head 6 4 MEASURING PROCEDURE 7 4 1 Humidity content...

Страница 3: ...ure linearity and precision cold junction compensation circuit high accuracy Microprocessor circuit assures maximum possible accuracy provides special functions and features Large LCD with two display...

Страница 4: ...ty Content High precision thin film capacitance sensor Temperature Thermistor Type K Thermocouple probe thermometer Data Hold Freeze the display reading by push button Memory Maximum Minimum value Rec...

Страница 5: ...Meter 195 x 68 x 30 mm 7 6 x 2 6 x 1 2 inch Humidity Probe length 600 mm Content Probe head diameter 10 mm Probe Cable length 1 5 meters Accessories Instruction manual 1 PC Included Humidity content p...

Страница 6: ...70 RH 3 RH Range 0 to 50 32 to 122 Temp Resolution 0 1 degree Accuracy 0 8 1 5 Dew Point Range 25 3 to 48 9 Resolution 0 1 Range 13 5 to 120 1 Resolution 0 1 Remark Dew Point display value is calculat...

Страница 7: ...Type K Thermometer Range 100 0 to 1300 0 Resolution 0 1 Accuracy 50 0 to 1300 0 0 2 0 5 50 1 to 100 0 0 2 1 Range 148 0 to 2372 0 Resolution 0 1 Accuracy 58 0 to 2372 0 0 2 1 58 1 to 148 0 0 2 1 8 5...

Страница 8: ...3 5 Button 3 6 Function Button 3 7 Battery Compartment Cover 3 8 Temp Probe input Socket 3 9 Humidity Probe input Socket 3 10 RS 232 Output Terminal 3 11 Stand 3 12 Probe Plug 3 13 Probe handle 3 14 P...

Страница 9: ...3 15 Fig 1 4 Penetrate the Sensing head 3 15 Fig 1 along with Probe main body 3 14 Fig 1 into the measurement materials such as Grain Corn Rice Cotton Paper refer to Fig 2 The meter s display will sho...

Страница 10: ...3 6 Fig 1 the LCD will show the unit DEW or 4 3 Type K thermometer measurement 1 Take out the humidity probe away from the Humidity Probe input Socket 3 9 Fig 1 If not take out the humidity probe the...

Страница 11: ...he maximum value just press the Hold Button 3 4 Fig 1 for a while then the display will show the REC symbol only execute the memory function continuously b Press the REC Button 3 3 Fig 1 again the REC...

Страница 12: ...on the front panel However in general conditions customers are always not recommended to execute the Offset Temperature Adjustment Procedures without qualified calibration equipment Offset Temp Adjust...

Страница 13: ...er digits 0 0 0 2 6 When desired value available release the fingers from the Hold Button 3 4 Fig 1 and REC Button 3 3 Fig 1 to finish the Offset Temperature Adjustment Procedures CONSIDERATION The ca...

Страница 14: ...ata Record function with a REC symbol on the display for long period measurement 7 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5 mm terminal 3 10 Fig 1 The data outp...

Страница 15: ...D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D8 to D1 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D0 End Word...

Страница 16: ...ple 40 to 482 Probe Ultra fast response naked bead Model TP 01 thermocouple general purpose application Type K Measure Range 50 to 900 Thermocouple 50 to 1650 Probe Dimension 10 cm tube 8 mm Dia Model...

Отзывы: