background image

HomeWorks Digital 0.1% Constant Voltage Controller

®

S P E C I F I C AT I O N   S U B M I T TA L

Page

Job Name:

Job Number:

Model Numbers:

LED Dimming Controller

Architectural Dimming

3691213a   9   06.01.21

Wiring 

(continued)

LHD0 Models: HomeWorks Digital Controls

 

 

Compatible Controls with Soft-on, Fade-to-Black dimming technology: Lutron HomeWorks Digital Controls

Guaranteed performance specifications with the controls listed in the chart below.
For assistance selecting controls, contact our LED Center of Excellence at 

1.844.LUTRON1

 (U.S.A. and Canada 

only) or 

[email protected]

Product

Model Number

Recommended 

System Version

Controllers per Control

120 V

~

277 V

~

HomeWorks QSX

LQSE‑2HDC‑D

10 or higher

64 per HomeWorks

digital link

1

  For the maximum wire length between the LED controller and the start of the linear strip, see charts in the 

Controller Wiring and Mounting

 section.

HomeWorks  

Digital 

0.1 % Constant 

Voltage  

LED Controller

To HomeWorks Digital Link

LED  

Light 

Engine

Line / Hot  (L) 

LED+ 

1

LED– 

1

Neutral (N)

Ground

HD1 
HD2 

To line  

voltage

9

Содержание LHD0-96W24V-U UL

Страница 1: ...Guaranteed dimming performance when used with Lutron controls HomeWorks digital module Lutron 3 wire controls and interfaces Protected from miswires of input power up to 277 V to HomeWorks digital con...

Страница 2: ...100 to 0 1 1 LED lighting turns on to any dimmed level without flashing to full brightness Operating Voltage 120 277 V at 50 60 Hz Rated lifetime of 50 000 hours at 40 C 104 F ambient temperature and...

Страница 3: ...grounded by terminal connection Must be permanently connected fixed wiring for 277 V application Terminal blocks on the controller accept solid or stranded wire per terminal from 20 AWG to 12 AWG 0 5...

Страница 4: ...For wiring options see Wiring section pages 8 10 NOTE Specifications are subject to change without notice Output Voltage vs Output Power Output Power W Output Power W Output Power W Output Voltage V...

Страница 5: ...e Job Name Job Number Model Numbers LED Dimming Controller Architectural Dimming 3691213a 5 06 01 21 Enclosure Dimensions Measurements are shown as in mm Knockouts Sides 4 locations 1 2 in or 21 mm tr...

Страница 6: ...tural Dimming 3691213a 6 06 01 21 Mounting Options1 2 1 Any other mounting configuration will require additional mechanical support Improper installation may result in hazards to personnel or property...

Страница 7: ...links are wired as Class 2 or between the HomeWorks digital control and output terminals Option 2 when the HomeWorks digital links are wired as Class 1 For 3 wire control barrier could be placed in ei...

Страница 8: ...7 1 6 1 14 Maestro Wireless dimmer MRF2 F6AN DV 1 6 1 14 RadioRA 2 dimmer RRD F6AN DV 1 6 1 14 Dual voltage 3 wire dimmer 21 4 HomeWorks QS dimmer HQRD F6AN DV 1 6 1 14 Fluorescent 3 wire LED 3 wire 2...

Страница 9: ...chart below For assistance selecting controls contact our LED Center of Excellence at 1 844 LUTRON1 U S A and Canada only or LEDs lutron com Product Model Number Recommended System Version Controllers...

Страница 10: ...consult load manufacturer best practices for any additional consideration in load installation When connecting several LED light homeruns ensure that the wire lengths and wattages match as closely as...

Страница 11: ...erminal Make sure that the supply breaker to the controllers and HomeWorks digital link supply is OFF when wiring HD1 and HD2 terminals of the controllers can be daisy chained as shown to the right Us...

Страница 12: ...The Field Adjustment Knob cannot fix light level mismatch among loads on the same controller For example two homeruns of different wattage For increasing the minimum light output of all the controlle...

Страница 13: ...signed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in...

Отзывы: