1. FEATURES

 * 500 g measuring capacity with 0.1 g resolution.
 * Built-in self-calibration system, high precision.
 * RS 232 PC serial interface.
 * Full capacity tare function capability.
 * Only one control button on front panel, easy operation.
 * Battery or DC adapter power supply.
 * Large LCD display,  Stainless platform.
 * Durable & portable housing plastic case.
 * LOAD CELL transducer, high precision.
 * Gram and Oz display unit, select by rear switch.
 * Use exclusive microprocessor LSI-circuit, high reliability.

2. SPECIFICATIONS

Display

18 mm(0.7") LCD, 5 digits w/annunciator.

Measuring Capacity 500.0 g/17.6 oz.
Resolution

0.1 g/0.005 oz.

Min. Display Weight 0.3 g/0.015 oz.
Accuracy

0.1 % + 3 d)   * After the moment
  when the self-calibration be executed.

Unit  Select

g or oz, select by internal slide switch.

Sampling  Time

Approx. 0.8 second.

Tare  Control

Full capacity.

Transducer

Load cell.

Circuit

Exclusive LSI-circuit.

Data  Bus

RS-232 serial output.

Cabinet  Size

250  x  190  x  50  mm

Platform  Size

Round, 120 mm Dia.

Power  Supply

6 x 1.5V AA (UM-3) BATTERY,
or DC 9V adapter.

Power Consumption Approx. DC 27 mA.

1

Содержание GM-500

Страница 1: ...SCALE marks a step forward for you into the field of precision measurement Although this DIGITAL SCALE is a complex and delicate instrument its durable structure developed Please read the following in...

Страница 2: ...Button 2 3 3 Display 2 3 4 Power Switch 2 3 5 Rubber Pads 2 3 6 Battery Cover Compartment 2 3 7 DC 9V receptacle 2 3 8 RS232 Output Socket 2 3 9 Calibration Face Plate 2 3 10 Unit Switch 2 4 PLATFORM...

Страница 3: ...clusive microprocessor LSI circuit high reliability 2 SPECIFICATIONS Display 18 mm 0 7 LCD 5 digits w annunciator Measuring Capacity 500 0 g 17 6 oz Resolution 0 1 g 0 005 oz Min Display Weight 0 3 g...

Страница 4: ...hat use WT 200 optional for executing the self calibration RS 232 cable RS 232 cable for connecting between Model UPCB 01 scale the computer optional Software Counting scale software optional SCALE U0...

Страница 5: ...3 2 Calibration Button 3 2a Tare Button 3 3 Display 3 4 Power Switch 3 5 Rubber Pads 3 6 Battery Cover Compartment 3 7 DC 9V receptacle 3 8 RS232 Output Socket 3 9 Calibration Plate 3 10 Unit Switch 4...

Страница 6: ...but the LCD display will not show any marker 3 Turn the Power Switch 3 4 Fig 1 to the On position The Display 3 3 Fig 1 will show 8 8 8 8 8 for a few seconds then 0 will appear again 4 Apply the load...

Страница 7: ...for the measurement accurately Consideration of Self Calibration The internal Self Calibration correction data is save to the memory circuit a while Once power off then the correction data will disapp...

Страница 8: ...the scale is ready for ACV operation 9 RS232 PC SERIAL INTERFACE The instrument features an RS232 output via 3 5 mm Terminal 3 8 Fig 1 The connector output is a 11 digit data stream for gram 12 digit...

Страница 9: ...CR Enter code is A D1 LF LF Line feed code is D D2 g D3 to D5 SPACE D6 to D9 Display reading D6 LSD D9 MSD D10 SPACE oz 12 digit data stream D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 Each digit indicate the...

Отзывы: