Tag and disconnect wires from the existing switch
Different
Color Screw
Ground
(Green / Bare Copper)
Place tag - to identify wire on
different color screw
Location 1
Multi-Location Installation - Caséta Claro Smart Switch with Pico Remote Controls (DVRF-5NS)
Neutral
connection
required
8
Connect the new Caséta Claro Smart switch
Tagged Wire
Ground
(Green Wire)
Location 1
Red
Blue
Black
White
Neutral
connection
required
7
Ganging and derating
Important note:
Ganging units together may reduce the switch’s maximum wattage
rating. See the chart below for maximum wattage information.
1
Neutral required.
2
The maximum lamp wattage is determined by the efficiency of the transformer, with
70% – 85% as typical. For actual transformer efficiency, contact either the fixture or
transformer manufacturer. The total VA rating of the transformer(s) shall not exceed the VA
rating of the switch.
3
The switch is UL
R
Listed for use with all magnetic and electronic fluorescent ballasts.
DVRF-5NS (120 V
~
)
1
LED
5 A
5 A
5 A
Halogen / incandescent
600 W
600 W
600 W
Electronic Low-Voltage
600 VA
600 VA
600 VA
Magnetic Low-Voltage
2
600 VA
600 VA
600 VA
Fluorescent
3
5 A
5 A
5 A
General Purpose Fan
3 A
3 A
3 A
A
B
C
Note: Claro Smart controls don’t have fins but derating is
still required. See the chart below.
B B
B C
B
A
9
Mount the Caséta Claro Smart switch
Location 1
10
Attach the wallplate
‘snap’
Wallplate
Adapter
Wallplate
Location 1