S
ERIAL
I
NTERFACE
D
EVELOPERS
G
UIDE
Factory
Bit Fields
Adr Entry Name
Mode
Initialize
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
66
Reticle B
Short
0x00DC
Horizontal
R/W
Position
68
Reticle B
Byte
0x78 NTSC
Vertical
R/W
0x80 PAL
Position
69
Reticle B
Byte
0x00
Emissivity
R/W
70
Reticle
Short
0x0000
Radiometric
R/W
Control
72
AGC
Byte
0x02
Mode
R/W
73
Active
Byte
0x00
ROI
R/W
Index
74
Reserved
Short
0x0000
R/W
76
Display Video
Short
0x0000
Manual
R/W
Low Intensity
78
Display Video
Short
0x3FFF
Manual
R/W
High Intensity
80
AGC High
Short
0x3FFF
Limit
R/W
Intensity
Display Video Manual Low Intensity (Input Intensity Mapped to 0)
(0 to 16,383)
Agc
Mod
Act Roi
Indx
Reserved
Reserved
Reserved
Reserved
Reserved
Reticle B Vertical Position
Reticle B Horizontal Position
Reserved
Reticle B Emissivity
( 0 to 1 - 2
-8
)
Display Video Manual High Intensity (Input Intensity Mapped to 255)
(0 to 16,383)
Reserved
Tem
p
Unit
AGC Low Limit Intensity
Reserved
Reticle Parameters:
If Rtcl X En = 1, then Draw Reticle X at the Reticle X Horizontal / Vertical Position.
If Reticle Emissivity is 0, Report Intensity on Overlay.
If Reticle Emissivity is not 0 Report Temperature on Overlay.
Reticle Radiometric Control:
Temp Unit
0 – Display Temperatures in Fahrenheit;
1 – Display Temperatures in Celsius
AGC Mode:
Agc Mod
0 – AGC/ALC Off (Hold Present State);
1 – Manual Contrast Adjust;
2 – Linear AGC/ALC;
3 – Histogram AGC/ALC;
4 to 15 – Reserved
Active ROI Index:
Selects the Currently Active ROI Index (0 <= Act ROI Index <= 7).
Use the Appropriate Op Mode Descriptor Table Values to Load the FPA Processor Registers.
Display Video Manual Low / High Intensity Parameters:
If Agc Mod = 1, then:
Intensity Transform = (Input – Manual Low Intensity) * (255/(Manual High Intensity – Manual
Low Intensity)).
AGC Limit Intensity Parameters:
See below.
54