7. Unscrew the back of the connector to reveal the terminals. Fit the strain relief and gland nut over the
cable BEFORE wiring the connector.
8. Wire the connector as shown below. TAKE CARE to secure the wires well with the grub screws. Check for
any stray strands that could short to the other pins before fitting the strain relief and gland nut.
Note: Check the wiring is correct before connecting to the hub. Incorrect wiring can damage the light.
Field Installable
Connector terminals
viewed from cable side
RED
(12 or 24 V DC)
BLACK
(Ground)
YELLOW
(Data)
BACK VIEW
BLACK
(Ground)
RED
(12 or 24 VDC)
YELLOW
(Data)
FRONT VIEW
9. Fit and tighten the strain relief and gland nut onto the connector. Plug into the hub, taking care to orient
the key correctly. Tighten the cap to make the waterproof seal.