This Control is designed to operate Only ONE Ceiling 

Fan .
NOTE: Electric connections should be in 

accordance with the National Electrical Codes and 

all Local Codes. Before starting, disconnect power 

to the circuit at the fuse box or circuit breaker 

panel.
Remove the Faceplate and Screws from the Existing 

Wall Switch . Pull Wall Switch out from Wall Box 

(Figure 19) .

7. Installing the Wall Control

SCREWS

WALL BOX

EXISTING WALL SWITCH

FACEPLATE

SCREWS

Figure 19

Determine the “HOT” Wire and the “LOAD” Wire and 

disconnect these Wires from the Existing Wall Switch .
NOTE: Do not attempt to disconnect any Wires not 

already connected to Existing Wall Switch.

7.2

NOTE: Make all wiring connections using 

wire connectors (supplied). Make sure that all 

connections are tight, including ground, and that 

no bare wire is visible at the wire connectors, 

except for the ground wire. 
NOTE: Set the Fan Control to the OFF position.

Connect the Fan Control Black Wire labeled 

“TO POWER SUPPLY” to the “HOT” 120V AC Supply 

Source Wire . Securely connect Wires with Wire 

Connector, supplied (Figure 20) .
Connect the Fan Control Black Wire labeled 

“TO FAN” to the “LOAD” Black Wire in Wall Box . 

Securely connect Wires with Wire Connector, supplied 

(Figure 20) .
Connect the Fan Control Green Ground Wire to the 

Supply Ground Conductor (this may be a bare wire or 

wire with Green Colored insulation) . Securely connect 

Wires with Wire Connector, supplied (Figure 20) .

4-SPEED SLIDE

CEILING FAN

CONTROL

OFF

POSITION

TO FAN MOTOR LOAD

1.25 AMP MAXIMUM

TO NEUTRAL

TO 120VAC

SOURCE HOT

BLACK WIRES

BLACK WIRES

TO POW

ER 

SUPPLY

TO FAN

HOT

LOAD

GREEN GROUND WIRES

M2

M1

L

H

OFF

Figure 20

Check to see that all connections are tight and that no 

bare wires are visible at the wire connectors.

 

WARNING

!

Do not connect any neutral (white) wire to this control. 

Incorrect wiring will damage this control.

 

WARNING

!

Turning off wall switch is not sufficient. To avoid 

possible electrical shock, be sure electricity is turned 

off at the main fuse box or circuit breaker panel before 

wiring. All wiring must be in accordance with National 

and Local codes and the ceiling fan must be properly 

grounded as a precaution against possible electrical 

shock.

 

WARNING

!

Содержание Kathy Ireland Home TILO CF130BS00

Страница 1: ...Fan Owner s Manual Model Numbers CF130BS00 Brushed Steel CF130ORB00 Oil Rubbed Bronze CF130WW00 Appliance White Net Weight 10 6 Lbs READ AND SAVE THESE INSTRUCTIONS MODERN 1 800 777 4440 www luminanc...

Страница 2: ...thod of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE This fan is suitable for use with solid state speed controls NO...

Страница 3: ...er Ball 4 5 Downrod Assembly 1 I SW46W Wall Control 1 1 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration HARD...

Страница 4: ...t the main fuse box or circuit breaker panel before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible...

Страница 5: ...ad blade screws Figure 1 NOTE Take care not to scratch fan housing assembly when installing blades Complete the remaining two blades installation per the above instructions Remove the three M4 x 8mm f...

Страница 6: ...r coupler Install the clevis pin and secure with the hairpin clip Figure 5 The clevis pin must go through the holes in the motor coupler and the holes in the downrod Be sure to push the straight leg o...

Страница 7: ...he two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the...

Страница 8: ...s from the top of the motor housing Figure 9 Position the rubber gasket supplied in parts bag on the motor housing small holes in gasket centered over the screw holes in the housing Figure 9 Position...

Страница 9: ...or less WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box...

Страница 10: ...anger bracket Pass the hook on the hanger bracket through one of the screw holes not the slots in the ceiling cover Figure 14 The hook must pass from the inside of the ceiling cover to the outside The...

Страница 11: ...E FAN WIRE Figure 16 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 16 Securely connect the fan motor black wire to the supply black ho...

Страница 12: ...CREW FAN HOUSING CEILING COVER INSTALL SCREW AND LOCKWASHER Figure 17 NOTE When installing the ceiling fan using the close to the ceiling method carefully lift the fan assembly from the hook on the ha...

Страница 13: ...beled TO POWER SUPPLY to the HOT 120V AC Supply Source Wire Securely connect Wires with Wire Connector supplied Figure 20 Connect the Fan Control Black Wire labeled TO FAN to the LOAD Black Wire in Wa...

Страница 14: ...for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cl...

Страница 15: ...on at the Main Fuse Box or Circuit Breaker Panel During Summer Months run the Fan Counter Clockwise as you look up at it to direct airflow downward During the Winter Months run the Fan Clockwise as yo...

Страница 16: ...16 U L Model No CF130 11 Repair Parts 16 17 10 8 20 13 9 18 7 19 1 21 22 12 4 0 3 2 1 3 2 4 6 11 14 15 5 M2 M1 L H OFF...

Страница 17: ...embly 2 Hanger Ball 3 Downrod 4 5 4 Cover Ceiling 764029 BS 764029 ORB 764029 WW 5 Decorative Upper Cover 2 764030 BS 764030 ORB 764030 WW 6 Decorative Lower Cover 764031 BS 764031 ORB 764031 WW 7 Cou...

Страница 18: ...are loose 3 Check to make sure the screws which attach the fan blade to the motor are tight 3 Fan wobbles 1 Set screws in motor coupler are not 1 Raise coupler cover and tighten setscrews securely exc...

Страница 19: ...nance Brands Ceiling Fan Product component or Luminance Brands Ceiling Fan Product accessory caused by normal wear and tear rather than due to defects in materials or workmanship Loss or damage result...

Страница 20: ...fan housing The date code can be found on the carton and on top of the fan housing stamped in ink on a white label You should record this data above and keep it in a safe place for future use Questio...

Отзывы: