background image

12

  

 U.L. Model No.: CF905-1

7.1

This Control is designed to operate Only ONE Ceiling 

Fan .
NOTE: Electric connections should be in 

accordance with the National Electrical Codes and 

all Local Codes. Before starting, disconnect power 

to the circuit at the main fuse box or circuit breaker 

panel.

7. Installing the Wall Control

SCREWS

WALL BOX

EXISTING WALL SWITCH

FACEPLATE

SCREWS

Figure 19

7.2

NOTE: Make all wiring connections using 

wire connectors (supplied). Make sure that all 

connections are tight, including ground, and that 

no bare wire is visible at the wire connectors, 

except for the ground wire. 
NOTE: Set the Fan Control to the OFF position.

Connect the Fan Control Black Wire labeled 

“TO POWER SUPPLY” to the “HOT” 120V AC Supply 

Source Wire . Securely connect Wires with Wire 

Connector, supplied (Figure 20) .
Connect the Fan Control Black Wire labeled 

“TO FAN” to the “LOAD” Black Wire in Wall Box . 

Securely connect Wires with Wire Connector, supplied 

(Figure 20) .
Connect the Fan Control Green Ground Wire to the 

Supply Ground Conductor (this may be a bare wire or 

wire with Green Colored insulation) . Securely connect 

Wires with Wire Connector, supplied (Figure 20) .

4-SPEED SLIDE

CEILING FAN

CONTROL

OFF

POSITION

TO FAN MOTOR LOAD

1.25 AMP MAXIMUM

TO NEUTRAL

TO 120VAC

SOURCE HOT

BLACK WIRES

BLACK WIRES

TO POW

ER 

SUPPLY

TO FAN

HOT

LOAD

GREEN GROUND WIRES

M2

M1

L

H

OFF

Figure 20

Remove the Faceplate and Screws from the Existing 

Wall Switch . Pull Wall Switch out from Wall Box .
Determine the “HOT” Wire and the “LOAD” Wire and 

disconnect these Wires from the Wall Switch (Figure 19) .
NOTE: Do not attempt to disconnect any Wires not 

already connected to Existing Wall Switch.

Check to see that all connections are tight and that no 

bare wires are visible at the wire connectors.

 

WARNING

!

Do not connect any neutral (white) wire to this control. 

Incorrect wiring will damage this control.

 

WARNING

!

Turning off wall switch is not sufficient. To avoid 

possible electrical shock, be sure electricity is turned 

off at the main fuse box or circuit breaker panel before 

wiring. All wiring must be in accordance with National 

and Local codes and the ceiling fan must be properly 

grounded as a precaution against possible electrical 

shock.

 

WARNING

!

Содержание Kathy Ireland Home Prima Snugger CF905BS01

Страница 1: ...l Model Numbers Net Weight 18 3 Lbs CF905BS01 Brushed Steel CF905ORB01 Oil Rubbed Bronze CF905SW01 Satin White CF905VNB01 Venetian Bronze READ AND SAVE THESE INSTRUCTIONS TRADITIONAL M2 M1 L H OFF 1 8...

Страница 2: ...0 2017 and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installatio...

Страница 3: ...from the protective plastic bag Place the Fan Assembly into the upper foam pad with the Wires facing up The upper foam pad serves as a holder for the Fan during the first stages of assembly 4 0 3 2 1...

Страница 4: ...nly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING To avoid fire or shock follow all wiring instr...

Страница 5: ...ed electrician if in doubt WARNING 3 1 Disconnect Electrical Power to the Branch Circuit at the Circuit Breaker Panel or Main Fuse Box before attempting to install the Ceiling Fan Hanger Bracket on th...

Страница 6: ...o Wire the Ceiling Fan This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Luminance Brands Substitu...

Страница 7: ...tor supplied Figure 6 Cap the Fan Motor Assembly Blue Wire with a 12 ga Wire Connector supplied if using the supplied Wall Control Figure 6 NOTE If you are using an Luminance Brands Light Fixture with...

Страница 8: ...rds and mate it up against the Ceiling Mounting Plate Align and rotate the Fan Motor Assembly to engage the Two Keyhole Slots with the Ceiling Mounting Plates Two Loosened Screw Heads Figure 9 Securel...

Страница 9: ...EAD SCREWS 5 5 Position the Fan Housing Cover over the Fan Motor Assembly Align and rotate the Fan Housing Cover to engage the Two Slotted Holes of the Fan Housing Cover with the Ceiling Mounting Plat...

Страница 10: ...not to scratch the fan housing when installing the blade assemblies SWITCH HOUSING CONNECTOR REMOVE SWITCH HOUSING MOUNTING SCREWS 4 MOTOR CONNECTOR 5 9 Engage the Switch Housing Assembly Connector wi...

Страница 11: ...0 if you have any questions about installation and operation of this Ceiling Fan Ceiling Fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are...

Страница 12: ...Ground Conductor this may be a bare wire or wire with Green Colored insulation Securely connect Wires with Wire Connector supplied Figure 20 4 SPEED SLIDE CEILING FAN CONTROL OFF POSITION TO FAN MOTO...

Страница 13: ...Screws Figure 21 Leave the Fan Control in the OFF mode until Fan installation is completed Position the Faceplate supplied onto the Fan Control Using the Two supplied 6 32 x 1 4 Screws Screw the Facep...

Страница 14: ...y to the opposite position and turn the Ceiling Fan ON again Figure 23 The Fan Blades will turn in the opposite direction and reverse the airflow Reverse Switch Information Season Blade Rotation Direc...

Страница 15: ...eck to make sure wire connectors in switch housing rattling are not rattling against each other or against the interior wall of the switch housing 5 Screws holding blades to flanges are loose 5 Tighte...

Страница 16: ...16 U L Model No CF905 1 10 Repair Parts 2 1 12 14 3 6 7 11 10 4 9 5 PARTS BAG 9 15 10 11 12 13 14 8 4 0 3 2 1 M2 M1 L H OFF...

Страница 17: ...1 2 Fan Housing Trim Ring 764130 BS 764130 ORB 764130 SW 764130 VNB 3 Fan Housing Cover 764131 BS 764131 ORB 764131 SW 764131 VNB 4 Fan Blades 5 per set 765174 DC CH 765174 DC WA 765174 SW MP 765174...

Страница 18: ...Ceiling Fan Controls Ceiling Fan Light Kits 12 Accessories The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING Do not use water w...

Страница 19: ...inance Brands Ceiling Fan Product component or Luminance Brands Ceiling Fan Product accessory caused by normal wear and tear rather than due to defects in materials or workmanship Loss or damage resul...

Страница 20: ...e fan housing The date code can be found on the carton and on top of the fan housing stamped in ink on a white label You should record this data above and keep it in a safe place for future use Questi...

Отзывы: