LDD-600/1000/1500-XX-YY Interface 

(Where XX = Iout

max

, and YY = Vout

max

Connector Type:  15 pin D-sub Female 

(Refer to Figure 3, LDD Interface Schematic) 

 

Pin  # 

Pin Name 

Functional Voltage 

Level  

Description 

Enable 

(input)  

High = RUN = +5V to 

+15V 
Low =  OFF = 0V               

The 

Enable

 function turns the output 

section of the power supply ON and 
OFF.  When the power supply is 

enabled, current is delivered to load 

as programmed via 

Ip)

Pin 7.   Rise times resulting from 

Enable

 are approximately 25msec.   

2 N/C 

 

 

Interlock  

(input) 

Open = OFF 

Connect to GND = RUN        

The 

Interlock

 function can be 

connected to external interlock 
switches such as door or overtemp 

switches. 

GND 

 

Referred to (-) output of power 

supply.   

Vout Monitor

:   

(output) 

0 – 10V = 0 – Vout

max

*

 

 

The output voltage of the supply can 

be monitored by 

Vout Monitor

Iout Monitor 

(output) 

0 – 10V = 0 – Iout

max

 

The output current of the supply can 

be monitored by 

Iout Monitor

.  

Ip)

:  

(input)  

0 – 10V = 0 – Iout

max

 

The power supply output current is 

set by applying a 0-10V analog signal 

to 

Ip)

.   

8 N/C 

 

 

GND 

 

Referred to (-) output of the power 

supply. 

10,11 

+5V @ 0.5A 

(output) 

 

Aux5V power supply for user.  

Up to 0.5A output current capability. 

12 

-15V @0.5A

 

(output) 

 

Auxiliary -15V power supply for user.  

Up to 0.5A output current available. 

 

13,14 

+15V @0.5A 

(output) 

 

Aux15V power supply for user.  

Up to 0.5A output current available. 

15 

Gnd 

 

Referred to (-) output of the power 

supply. 

 

 

TABLE 1:  LDD-600/1000/1500 Interface 

 
*  If maximum compliance voltage is less than 10V, 

Vout Monitor

 will read output 

voltage directly.  If maximum compliance voltage is greater than 10V, then 

Vout Monitor

 

will be scaled such that 0-10V = 0-Vout

max

.

  

 
 

Содержание LDD-1000 Series

Страница 1: ...tage capability depending on the user s requirements LDD power supplies will deliver current as programmed into any load providing the voltage requirements of that load do not exceed the maximum rated...

Страница 2: ...s 5 LDD 600 1000 1500 Interface 7 INSTALLATION AND OPERATION 9 Optional RS 232 Protocol 12 Tables and Figures LDD Laser Diode Power Supply Block Diagram 4 LDD 600 1000 1500 Outline Drawing 6 LDD 600 1...

Страница 3: ...er This inverter boosts the input voltage to 400VDC In the process of boosting the input AC voltage the input AC current is adjusted so that is always in phase with the input AC voltage Without this p...

Страница 4: ...e EMI noise and a reduction in overall system heatsink requirements Output Circuit The output filter is a two stage RC filter designed to keep ripple and output noise very low Control Circuit The cont...

Страница 5: ...rent Voltage Monitor 0 10V for 0 Max Voltage Performance Rise Fall Time 600usec 10 to 90 Full Current Current Regulation 0 5 of Maximum output current Temperature Drift 0 5 over temperature range afte...

Страница 6: ...02001027 Rev 1 ECO 7062 Operation Manual LDD 600 1000 1500 XX YY Page 6 of 13 Figure 2 LDD 600 1000 1500 Outline Drawing...

Страница 7: ...y 5 Vout Monitor output 0 10V 0 Voutmax The output voltage of the supply can be monitored by Vout Monitor 6 Iout Monitor output 0 10V 0 Ioutmax The output current of the supply can be monitored by Iou...

Страница 8: ...02001027 Rev 1 ECO 7062 Operation Manual LDD 600 1000 1500 XX YY Page 8 of 13 Figure 3 LDD 600 1000 1500 Interface...

Страница 9: ...re 4 Although the user interface is typically designed by the user Lumina Power can provide any assistance necessary to modify interface program and monitor levels See Table 1 and Figure 3 for descrip...

Страница 10: ...gram Pin 7 A 0 10V signal results in 0 to Ioutmax as long as the rated compliance voltage of the driver is not exceeded 4 Operating the LDD a AC INPUT POWER CONNECTION Connect AC power connections to...

Страница 11: ...ver output current as programmed 5 Monitoring LDD output and performance a Current Monitor Power supply output current can be monitored via pin 6 Iout Monitor A 0 10V signal will represent the output...

Страница 12: ...supply and reading back the output current and voltage The output can be turned on and off with a command as well Command Reply Function Pxx xx xx xx cr cr Program output current to max rated output c...

Страница 13: ...Interface Schematic Pin Pin Name Functional Voltage Level Description 3 Interlock input Open OFF Connect to GND RUN The Interlock function can be connected to external interlock switches such as door...

Отзывы: