6.3.4
Battery type
When the LCD shows
left, press the
MENU
key for 1s,the
icon flashes , you can set the battery type.
as displayed at
Battery type
GEL(Default)
Liquid
Lithium
AGM
Display
1.
C
harging Voltage Parameters
(
Liquid, GEL, AGM)
When choosing Liquid, GEL or AGM for battery type, the parameters of boost,
and float
charge voltage can be set by IoT, RS485 or bluetooth APP. The range of parameters is as follows.
The following voltage parameters are 25℃/12V system parameters, 24/36/48V
displayed
values
are
multiplied
by
a
factor
of
2
/3/4.
equalization
Boost
Charging Voltage Range
Default charging voltage
Charging stage
14.0
~
14.8V
14.5V
14.0
~
15.0V
14.8V
13.0
~
14.5V
13.7V
Float
Equalization
2.
thium
The controllers are suitable for all kinds of lithium batteries.
When choosing lithium battery type, the
overcharge protection and overcharge recovery voltage of lithium battery can be set by IoT, RS485 or
bluetooth
APP
.
C
harge target voltage
range: 12/24V: 10.0-32.0V (default:14.4V)
12/24/36/48V: 10.0-64.0V (default:29.4V)
Charge recovery voltage
setting range: 12/24V: 9.2-31.8V (default:14.0V)
12/24/36/48V: 9.2-63.8V (default:28.7V)
C
harging Voltage Parameters
(
Li
)
Note: 1.
2. (
Overcharge Recovery 1.5V
)
≥Lithium Overcharge Protection Voltage≥
(
Overcharge Recovery 0.2V)
Parameter setting out of range is not supported
.
Max EU cannot be set as a lithium battery controller.
Warning: The required accuracy of BMS shall be at least 0.2V. If
tolerance
is
larger
than
0
.
2V
,
manufacturer
will
not
assume
any
liability
for
any
consequent
system
malfunction
.
6.3.5
L
oad mode
When the LCD shows
left, press the
MENU
key for 1s, the
icon flashes, you can set the load mode.
as displayed at
Display
Load mode
Always on Mode:
The load output is always switched on.
Dusk to Dawn Mode: The load output is
switched on between sunset and sunrise.
Evening Mode: The load output will be
switched on for 2~9hours after sunset.
Manual Mode: The load output can be
switched on and off manually by pressing
MENU
shortly.
1.Always on Mode
When the controller is set to always On mode, no matter the charging or discharging state, the
load is always powered on (except in protection state).
14
Содержание Max-E Series
Страница 5: ...3 Dimensions 3 96 62 53 4 5 176 189 5 8 15 12 24V ATUO Solar charge controller 3 1 Max20 30 40 EU...
Страница 6: ...4 Unit mm R2 25 4 4 50 4 50 138 90 187 50 177 88 5 62 50 Max50 60 E Max50 6048 E 3 2 Max50 60 48 E...
Страница 13: ...6 1 3 Press OK to browse the interface 6 1 2 The interface automatically cycles in the displayed sequence 11...