background image

LF1050-INS-LAB-RevH18

Read this manual before operating your Patient Lift.

Save this manual for future use.

LF1050 PATIENT LIFT

USER MANUAL

Содержание LF1050

Страница 1: ...LF1050 INS LAB RevH18 Read this manual before operating your Patient Lift Save this manual for future use LF1050 PATIENT LIFT USER MANUAL ...

Страница 2: ...TRUCTIONS 7 5 ASSEMBLY INSTRUCTIONS 8 CHARGING THE BATTERIES 11 CHECKING BATTERY CAPACITY 11 ALARM BUZZERS 11 6 OPERATING INSTRUCTIONS 12 LIFTING THE PATIENT 12 EMERGENCY RELEASE 16 7 CARE AND MAINTENANCE 17 BEFORE EACH USE 17 AT LEAST ONCE A MONTH 17 LUBRICATION 17 CLEANING 18 CARE OF SLINGS 18 MAINTENANCE SCHEDULE 18 8 TROUBLESHOOTING 19 9 SPECIFICATIONS 20 10 LIMITED WARRANTY 21 11 INDEX 23 ...

Страница 3: ...e several times with proper supervision and with a capable individual acting as patient It is extremely important to know how a patient will feel in the patient lift We suggest that the operator try all the various lifting slings and equipment until the operator is confident with how the patient lift operates The lifting procedures should be explained to the patient before the actual lifting Remem...

Страница 4: ...ice that if not avoided could result in product or property damage Info Provides application recommendations or other useful information to ensure that you get the most from your product WARNINGS WARNING Important Read and understand these instructions before assembling or using the Lumex LF1050 Patient Lift If you do not understand any part of these warnings cautions or instructions contact a hea...

Страница 5: ...he lift with the handle WARNING During lifting or lowering whenever possible always keep the patient lift legs in the maximum open position WARNING To facilitate movement close patient lift legs before moving the lift WARNING Replace any worn or broken parts immediately Torn cut frayed or broken slings can fail resulting in serious personal injury Use only slings that are in good condition WARNING...

Страница 6: ... COMPONENTS a Boom b Mast c Base d Spreader bar e Pendant f Actuator g Control box h Caster brake i Front caster j Emergency Lowering Device CONTROL BOX COMPONENTS RESET Button Battery Testing Charger Plug in Actuator Plug in Pendant Plug in ...

Страница 7: ...ts contents If damage is evident notify the carrier or your GF authorized distributor 2 Remove all loose packing from the carton 3 Carefully remove all the components from the carton Info Unless the patient lift is to be used immediately retain boxes containers and packing material for use in storing until use of patient lift is required Inspection 1 Examine the exterior of the patient lift for ni...

Страница 8: ...out assistance 1 Engage the lift brakes as shown above 2 Remove the bolts from the bottom of the mast and base 3 Pull the mast boom and spreader bar to an upright position as shown above 4 Reinstall the bolts in the holes at bottom of mast Tighten the nuts 5 Attach the control box hanging bracket to the mast as shown above Tighten the nuts ...

Страница 9: ...e mast bracket and insert retainer pin as shown above Insert retaining ring through retainer pin hole to secure actuator base to mast bracket 8 Attach the actuator top to the boom bracket and insert retainer pin as shown above Insert retaining ring through retainer pin hole to secure actuator top to boom bracket ...

Страница 10: ...ining ring through retainer pin to secure spreader bar to boom Pendant plug Actuator plug 10 Insert the actuator plug into the control box as shown above 11 Insert the pendant plug into the control box as shown above Info Before using the lift charge the batteries for ten to twelve hours see instructions on following page ...

Страница 11: ...motor from the control box Frequent plugging and unplugging of the hand control and motor to and from the control box may damage the control box CHECKING BATTERY CAPACITY Info To check remaining battery capacity press the battery indicator blue circle with battery symbol while the lift is not in motion Remaining battery capacity is indicated by LED indicator lights and explained in the following t...

Страница 12: ...fore lifting 1 Turn on the power by turning the RED RESET BUTTON clockwise 2 Press the hand pendant UP or DOWN button once 3 After the battery indicator lights de illuminate push the hand pendant UP button and DOWN button to ensure the lift is operating correctly 4 Position the lift base around or under the patient 5 Widen the base LIFTING THE PATIENT WARNING Do not attempt to transfer a patient w...

Страница 13: ...he sling to ensure a safe and comfortable sitting position as the patient is raised 9 Raise the patient until the buttocks are just above the mattress Lift the patient s legs and turn the patient to face the lifting column Move the patient lift away from the bed Ensure that the patient s arms and legs clear the patient lift bed or any other obstacles Lowering the patient onto a bed 1 Raise the pat...

Страница 14: ...ION before lowering the patient into the wheelchair or unexpected wheelchair movement could result which may result in serious injury to both the patient and the attendants 9 Position the patient over the wheelchair with their back against the back of the wheelchair 10 SLOWLY lower the patient into the wheelchair 11 With one attendant behind the wheelchair and the other operating the lift the atte...

Страница 15: ...he hand pendant to slowly lift patient maintaining patient s position facing attendant until patient s feet swing easily off the bed 10 Position patient above wheelchair or commode chair Lock lift brakes WARNING Before transfer ensure wheelchair or commode chair wheel locks are in locked position Wheelchair wheel locks must be in LOCKED POSITION before lowering the patient into the wheelchair or u...

Страница 16: ...ower The device consists of a plastic collar ring that should be turned clockwise continually until the patient has been lowered Contact your dealer immediately if standard troubleshooting techniques do not correct the failure Do not attempt to lift patients until all failure issues have been safely resolved Info The emergency lowering device is intended for use during lift failure This device wil...

Страница 17: ...ld create a hazardous condition which may result in serious injury and will void the warranty WARNING The electronics and actuator contain no serviceable components DO NOT attempt to open the electronics or actuator If service is required consult GF Tech Support at 1 770 368 4700 for further information When you believe a component or part is not functioning properly immediately contact GF Tech Su...

Страница 18: ...operation Read and observe the following recommended maintenance schedule Item Inspect Inspect Adjust initially monthly every 3 months Boom spreader bar Check connections between 1 boom and spreader bar and 2 boom and mast for improper connection looseness or wear X X Inspect boom for bending or deflection X X Mast Inspect mast for bending or deflection X X Inspect steering bar for damage or loose...

Страница 19: ...cycle The control box PCB may be malfunctioning The actuator will either go up or down but not both Replace the hand control as it is at the end of its life cycle The control box PCB may be malfunctioning There is a grinding sound inside the actuator when lifting Replace the actuator as the internal gears are stripped The actuator stops and starts while lifting or lowering Replace the batteries as...

Страница 20: ...d 26 Base height clearance 4 75 Base length 44 Lifting height range Info As measured from sling hooks Minimum 27 Maximum 69 Range 42 Mast height 50 Maximum weight capacity 400 lb 181 kg EVENLY DISTRIBUTED Caster size 4 diameter locking 3 diameter non locking Lifting mechanism 24 DC actuator Battery charger AC 110V 220V to DC 24V 1 amp ...

Страница 21: ...TAINING WARRANTY SERVICE This limited warranty shall only apply to defects that are reported to the Distributor from whom the Customer purchased the product within the applicable warranty period If there is not a Distributor you must contact GF directly by calling 1 770 368 4700 sending a fax request to 1 770 368 2386 or by e mailing a request to cs grahamfield com Specific directions will be prov...

Страница 22: ...PLOYEE OR INDEPENDENT CONTRACTOR WAGES PAYMENTS AND BENEFITS The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and understandings with respect thereto The recipient of this document hereby acknowledges and represents that it has not relied on any representation assertion...

Страница 23: ...Lowering the patient to the floor 14 Lubrication 17 M Maintenance schedule 18 N NOTICE statement significance 4 O Operating Instructions 12 R Removing the sling 14 S Safety precautions 4 Safety statements significance of 4 Shipping and transportation instructions 7 Specifications 20 Storage 7 T Transferring the patient from a bed to a wheelchair or commode chair 15 Transferring the patient from a ...

Страница 24: ... can be found on our website www grahamfield com 2005 GF Health Products Inc All Rights Reserved Graham Field and Lumex are trademarks of GF Health Products Inc One Graham Field Way Atlanta GA 30340 3140 GF Health Products Inc is an ISO 13485 Certified Company Manufactured for GF Health Products Inc Made in Taiwan ...

Отзывы: