34
a maximum value of 9999
<Remark>
The following port is used by the camera.
Setting of the port may not connect correctly
8554, 8556, 8557, 8080, 80, 81, 9090, 23
5
SRT Setting
1
.
Set the field of SRT and then check the item to open
SRT streaming
After the SRT streaming is opened, it will be connected
automatically upon startup
2. The port number must be set in the range above 1024
with a maximum value of 9999
<Remark>
The following port is used by the camera.
Setting of the port may not connect correctly
8554, 8556, 8557, 8080, 9090, 1935
3. Delay time is for 20 to 8000 microseconds. The default
value is 120 microseconds
V
6
SNTP/ Port Setting
1. Set SNTP Server IP
2. Set HTTP port. The default Port value is 80
Set HTTPS port. The default Port value is 81
<Remark>
Change of setting is available only when DHCP
function of camera is closed
V
V
7
Tracking Data Output
(FreeD)
When enabled, PTZ position information can be reported
when the camera moves
1. Serial Output: Please set the protocol to VISCA and the
baud rate to 38400
(Please refer to
5.2.13 Setting - Maintenance -
System Service
for relevant settings.)
2. IP output: Set the IP address and port
<Remark>
When Tracking Data Output is enabled, the
camera performance may be affected.
V
V
5.2.10
Setting - Time
No
Item
Function Descriptions
1
Time in Camera
Display the date and time of the camera
2
Set Time
Manual Configuration: Set time manually
Synchronize with computer time: Set the camera time according to the
computer time
Synchronize with SNTP server: Set the camera time synchronously with
the SNTP server
<Remark>
SNTP server address: Please change in network setting
1
2