AirGlow radio module integration guide

 

Version: 2  March 17, 2022 

 

LumenRadio AB 

www.lumenradio.com 

Phone: +46 31 301 03 70 

Svangatan 2B 

[email protected] 

Fax: +46 31 301 03 80 

SE-416 68 Gothenburg 
Sweden 

 

VAT reg. no: SE556761749201 

14

 

Compliance information 

14.1

 

FCC information 

14.1.1

 

FCC Information to User 

This product does not contain any user serviceable components and is to be used with approved 
antennas only. Any product changes or modifications will invalidate all applicable regulatory 
certifications and approvals 

14.1.2

 

FCC Guidelines for Human Exposure 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled 
environment. This equipment should be installed and operated with minimum distance of 20 cm 
between the radiator and your body. This transmitter must not be co-located or operating in 
conjunction with any other antenna or transmitter. 

14.1.3

 

FCC Declaration of Conformity 

We LumenRadio AB Svangatan 2B, 41668 Gothenburg, Sweden, declare under our sole 
responsibility that 840-2111 AirGlow complies with Part 15 of FCC Rules. Operation is subject to 
the following two conditions: 
 
This device may not cause harmful interference, and this device must accept any interference 
received, including interference that may cause undesired operation. 

14.1.4

 

FCC Radio Frequency Interference Warnings & Instructions¶ 

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no guarantee that interference will 
not occur in a particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following methods: 

 

Reorient or relocate the receiving antenna 

 

Increase the separation between the equipment and the receiver 

 

Connect the equipment into an electrical outlet on a circuit different from that which the 
radio receiver is connected 

 

Consult the dealer or an experienced radio/TV technician for help. 

Modifications made to the product, unless expressly approved by LumenRadio AB., could void the 
user’s right to operate the equipment. 

14.2

 

Industry Canada statement 

This digital apparatus does not exceed the Class B limits for radio noise emissions from digital 
apparatus set out in the Radio Interference Regulations of the Canadian Department of 
Communications. 
 

Содержание AirGlow

Страница 1: ...ol libraries available to simply drop onto existing layouts AirGlow is fully DALI2 and D4i compliant and only a few extra external components are required for built in wireless DALI based light contro...

Страница 2: ...9 6 1 DALI data interface reference design 10 6 2 DALI PSU reference design 11 7 RTC circuit 12 7 1 RTC reference design 12 7 2 Battery backup considerations 13 8 Layout considerations 13 8 1 Antenna...

Страница 3: ...Sweden VAT reg no SE556761749201 14 1 1 FCC Information to User 22 14 1 2 FCC Guidelines for Human Exposure 22 14 1 3 FCC Declaration of Conformity 22 14 1 4 FCC Radio Frequency Interference Warnings...

Страница 4: ...GHz ISM band 2402 2480 MHz Number of units Up to 200 in one meshing network Number of hops 8 hops in the meshing network Dimensions 18 5 mm x 33 5 mm Configuration data storage Highly secured storage...

Страница 5: ...31 301 03 70 Svangatan 2B sales lumenradio com Fax 46 31 301 03 80 SE 416 68 Gothenburg Sweden VAT reg no SE556761749201 1 2 Mechanical specification All dimensions in mm Mechanical design files in s...

Страница 6: ...Do not connect 5 N C No connection Do not connect 6 MISO Digital output SPI Master In Slave Out future use 7 VSS Power Ground 0V 8 N C No connection Do not connect 9 VSS Power Ground 0V 10 SDA Digital...

Страница 7: ...er Ground 0V 28 IRQ Digital output SPI Interrupt signal active low future use 29 N C No connection Do not connect 30 N C No connection Do not connect 31 N C No connection Do not connect 32 DALI RX Dig...

Страница 8: ...he first unit being commissioned and it is recommended to start commissioning of a central positioned AirGlow for best performance 3 1 Bluetooth connectivity and AirGlow app The AirGlow module is Blue...

Страница 9: ...the supply pin should be decoupled with a 100nF ceramic capacitor located as close to the supply pins as possible It is also recommended to add a high value capacitor ceramic close to the supply pin 6...

Страница 10: ...r Part number C1 C2 Not Mounted Not Mounted Not Mounted C3 CAP CER 8200PF 50V X7R 0402 Yageo CC0402KRX7R9BB822 C4 CAP CER 1000PF 50V NP0 0402 Yageo CC0402KRX7R9BB102 D1 Zener 6 5V 250mW SOT 23 Nexperi...

Страница 11: ...rcuit current of approx 50mA This circuit is sufficient to power a driver and the suggested DALI data interface as the current consumption in idle state will be 2mA for the AirGlow interface and 2mA f...

Страница 12: ...ttery backup type is recommended for absolute time keeping this will allow the AirGlow module to keep calendar time even during longer power outs and the battery will be charged when power is restored...

Страница 13: ...Capacity 25 C 3 5 mAh Time to discharge 5000 hours 208 days Capacity 40 C 1 2 mAh Time to discharge 1714 hours 71 days If the battery is discharged absolute time will be lost but absolute time will b...

Страница 14: ...ice that is placed on the main board Pay special attention to readymade LAN products Server in a RJ connector They pass EMC certifications but some of them radiate badly on 2 45 GHz If disturbances ca...

Страница 15: ...le antenna area Note that carrier board thickness can be included in the total distance to solid objects under the antenna I e for a 1 6mm carrier board standoffs needs to be min 3 4mm Carrier board c...

Страница 16: ...irGlow module Linx Technologies product number ANT DB1 WRT UFL Digi Key order code ANT DB1 WRT UFL ND PANEL MOUNT DOME ANTENNA FOR OUTDOOR USE A similar antenna to the Linx ANT DB1 WRT UFL but with a...

Страница 17: ...mance of up to 1500m line of sight can be expected using this antenna together with the AirGlow module LumenRadio order code 104 1015 FLAT PATCH ADHESIVE MOUNT ANTENNA FOR ABS PLASTIC ENCLOSURE An ind...

Страница 18: ...has an integrated low power DALI PSU Schematics and BOM of the AirGlow Arduino compatible shield is available for download on the AirGlow module support page 10 1 Zhaga book 18 connector wiring diagr...

Страница 19: ...ign verification and testing services please contact LumenRadio for advice for contact information see section 16 Contact and Ordering information 11 2 Production Testing All AirGlow modules are facto...

Страница 20: ...io com Phone 46 31 301 03 70 Svangatan 2B sales lumenradio com Fax 46 31 301 03 80 SE 416 68 Gothenburg Sweden VAT reg no SE556761749201 12 2 Reel marking Every reel has an identifier sticker booth on...

Страница 21: ...reflow meet the requirements of the solder paste The AirGlow module conforms to JSTD 020D1 standards for reflow temperatures Temperatures should not exceed the minimums or maximums presented in the ta...

Страница 22: ...n 14 1 4 FCC Radio Frequency Interference Warnings Instructions This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules The...

Страница 23: ...FCC certification Part 15 247 Transmitter tests An end product incorporating a AirGlow module does not require additional testing or authorization for the AirGlow transmitter or transceiver in the cas...

Страница 24: ...SE 416 68 Gothenburg Sweden VAT reg no SE556761749201 16 Contact and Ordering information LumenRadio AB Svangatan 2B SE 416 68 Gothenburg Sweden Phone 46 31 301 03 70 www lumenradio com sales lumenra...

Отзывы: