AirGlow radio module integration guide
Version: 2 March 17, 2022
LumenRadio AB
www.lumenradio.com
Phone: +46 31 301 03 70
Svangatan 2B
Fax: +46 31 301 03 80
SE-416 68 Gothenburg
Sweden
VAT reg. no: SE556761749201
6.1
DALI data interface reference design
Below is the schematics and BOM of the DALI interface from the AirGlow shield included in the
. Please note that adjustments of components values might be needed in
this circuit to meet the timing requirements of the DALI standard IEC 62386-101:
Min
Max
Rise/Fall time
3µs
15µs
Please consult IEC 62386-101 for definition of rise and fall time.
Reference
designator
Item name
Manufacturer
Part number
C1, C2
Not Mounted
Not Mounted
Not Mounted
C3
CAP CER 8200PF 50V X7R 0402
Yageo
CC0402KRX7R9BB822
C4
CAP CER 1000PF 50V NP0 0402
Yageo
CC0402KRX7R9BB102
D1
Zener 6.5V 250mW SOT-23
Nexperia USA Inc.
PLVA665A,215
Q1
BSS138BK MOSFET N-CH 60V 360MA
TO236AB
Nexperia USA Inc.
BSS138BK,215
Q2
2N7002P MOSFET N-CH 60V 0.36A SOT-23
Nexperia USA Inc.
2N7002P,215
Q3
BC847B NPN 45V 100mA
Nexperia USA Inc.
BC847B
R1
RES 2k2 1% 1/16W 0402
Yageo
RC0402FR-072K2L
R2, R6
RES 10K 1% 1/16W 0402
Yageo
RC0402FR-1310KL
R3, R5
RES 5k6 1% 1/16W 0402
Yageo
RC0402FR-075K6L
R4
RES 1k 1% 1/16W 0402
Yageo
RC0402FR-071KL
R7
RES 470k 1% 1/16W 0402
Yageo
RC0402FR-13470KL
The DALI_P_FUSED signal shall be tied to DALI+ and an input protection circuit is recommended.
Below is a schematic and BOM of the input protection circuit used on the AirGlow shield for
overvoltage and short circuit protection.