lumenstudio
™
software user manual
lumenstudio
™
software user manual
46
47
Scene (S):
Scene management
·
S 0(off) enable: displays an empty off scene before scene 0 in each area
·
S Pause enable: allows a scene to be paused if the scene mode button is held for 1 second
·
S Stop enable: allows a scene to be stopped if the scene mode button is held for 4 seconds
·
S Fade config : manages the fading between scenes
From Show : the fade time set inside the show file will be used
Force : the automatic fade time set in the menu will override all fadetimes in the show file
Force Max : the controller will look at the show file fade time and the menu fade time and use the greatest
Force Min : the controller will look at the show file fade time and the menu fade time and use the smallest
Never : the controller will never fade between scenes
·
S Fade time: the time of the automatic fade between scenes
·
S Auto reset: when enabled, any color, dimmer or speed overrides will be reset each time the scene is changed
·
S Trigger : sets the scene triggering mode. Time Delay and Scene Butt allow for scenes to be scrolled through without playing
Auto : the scene will be triggered as soon as it’s selected
Time Delay : a short delay is added before a scene is triggered
Scene Butt. : the selected scene will not play until the scene button is pressed
First Start (F):
Default settings when the unit is first powered up
·
F Scene Nr.: specify a default scene number
·
F Display Time: when enabled, the time will be displayed on the screen at startup
·
F Scene Nr.: enables the triggering of a scene at startup. If disabled, no scene will be triggered
Trigger (T):
Manages the controllers external triggering properties
·
T Time enable: enables the clock triggering
·
T Ports enable: enables the 8 dry contact ports
·
T RS232 enable: enables scene triggering by RS232
·
T IR enable: enables the infra red port (disabled by default to prevent interference)
·
T UDP enable: allows the controller to send and receive UDP messages required for network control
·
T Blackout port : enables the blackout relay output which is triggered when the standby button is touched
Ethernet (E):
Manages the controllers network settings
·
Ethernet: Enables the Ethernet socket on the controller
·
Dynamic IP Addr : enables dynamic IP addressing (DHCP) which allows the controller to obtain an IP address from a router
·
Sync Blackout: when this open is enabled, all other controllers on the network will go into standby when the standby
button
is
pressed
·
Enable NTP : enables Network Time Protocol. The controller will synchronise the clock with the internet if a connection is available
·
NTP Server : the IP address of the server to synchronize the clock. The default is 005.135.141.108
·
Device’s IP Add: the controller’s static IP address it will use if it does not receive an IP address via DHCP
·
Mask: the subnet mask of the controller if not set to DHCP. Generally this is 255.255.255.0
·
Default Gateway : the IP address of the router if not set to DHCP
·
MAC Address : a unique ID used to identify the controller on the network
Date/Time (D):
Manages the date and time stored inside the controller
·
Date: the controller’s date
·
Time: the controller’s clock time
Graphics (G):
Screen management
·
G Image enable: allows for images to be shown for each scene if they have been assigned in the programming software
·
G Image full: when enabled, the image will be displayed in full screen and the scene and area will not be visible
·
G Image time: the time it takes before the image is displayed in full screen
·
G Sleep enable: when enabled, the screen brightness will dim after a certain amount of time
·
G Sleep time: the amount of time to wait before sleeping
·
G Bright normal: the % brightness when the controller is not sleeping
·
G Bright sleep: the % brightness when the controller is sleeping
·
G Bright LED: the % brightness of the mode and reset LEDs
DMX Output (X):
Manage the timings of the DMX output messages and the page priorities (advanced function!)
·
X MBB: Mark Before Break- the time to wait between sending each 512 channel DMX message (or ‘packet’)
·
X Break: Break- the time to wait just before sending a new packet, resetting the DMX line
·
X MAB: Mark After Break- the message which tells your receiver to begin reading data
·
X MBS: Mark Between Slots- the delay time between sending each DMX channels data within the DMX packet
·
Univ-1/Univ-2: each timing can be set differently depending on the universe number
·
X Alphab Mode: if the same scene is triggered in the global area and a second area, the area with the highest letter will take
priority
·
X LTP Mode: if the same scene is triggered in the global area and a second area, the latest scene triggered takes priority
Sensitive (S):
Manage the touch sensitivity settings
·
S USB Init: reset the touch sensitivity when the USB is connected and disconnected
·
S Auto Time: the time to wait before automatically resetting the touch sensitivity
·
S High Sense: when enabled, the sensitivity will be increased
·
S See Values: see each touch sensitive button number and palette value
Language (L):
change the language of the text which appears on the screen
About:
Check the firmware release date and version number and assign a name for the controller
Reset:
reset all settings to the factory default