INSTALLATION:
Location - It is important that the installation location is carefully considered, avoiding shady areas. The best solar panel position
is south facing, however the light can work facing in other directions when in full sunshine. The PIR must face the direction in
which the motion is to be detected. Ensure there is no other lights which could interfere with the Sensors, imitating daylight.
To be mounted on a wall or lamp post at a height of
3-6m
.
LAMP POST
–
Straight Pole (50-60mm diameter)
TURN ON THE LAMP PRIOR TO INSTALLATION (see modes & settings)
1.
Ensure the 4 x bottom socket screws on the fitting
are tightened with the allen key provided.
2.
Hook a U-Brackets around the back of the lamp post
at the desired height and insert them into one set of
centre holes of the lamp bracket from behind.
3.
Fasten the 2 x washers, lock washers and nuts onto
the front of the U-Bracket at the inner side of the
lamp bracket to secure the lamp in position. Repeat
steps 2 and 3 with second U-Bracket.
4.
Optional Tilt
–
loosen the 2 x screws on both sides
of the lamp to adjust the lamp angle. Adjust up to 20
degrees upwards and 10 degrees downwards. Re-
tighten screws when positioned at desired angle.
LAMP POST
–
Angled Pole (50mm diameter)
TURN ON THE LAMP PRIOR TO INSTALLATION (see modes & settings)
1.
Remove the standard bracket via the 4 x socket
screws / washer / lock washer with the allen key.
2.
Loosen the 4 x bottom socket screws to adjust the
inner pole entry bracket to match the pole. Note:
push the inner adjustable bracket upwards so the
inner edge clears the 50mm hole and to pull the
loosened screws back to the fitting. Do not
completely remove screws.
3.
Insert the pole into the pole entry of the lamp to full
depth.
4.
Ensure the lamp is in the correct position and re-
tighten the four screws loosened in step 2 to lock the
lamp into place on the angled pole.