Lumena VIAMAX Hiway MAX 40W PIR Solar Street Light Скачать руководство пользователя страница 2

Full product range & more information: 

www.lumenalights.com

 

INSTALLATION:

  

 

Location - It is important that the installation location is carefully considered, avoiding shady areas. The best solar panel position 
is south facing, however the light can work facing in other directions when in full sunshine. The PIR must face the direction in 
which the motion is to be detected. Ensure there is no other lights which could interfere with the Sensors, imitating daylight. 

 

To be mounted on a wall or lamp post at a height of 

3-6m

.  

 

 
LAMP POST 

 Straight Pole (50-60mm diameter) 

 
TURN ON THE LAMP PRIOR TO INSTALLATION (see modes & settings) 
 

1.

 

Ensure the 4 x bottom socket screws on the fitting 
are tightened with the allen key provided. 

2.

 

Hook a U-Brackets around the back of the lamp post 
at the desired height and insert them into one set of 
centre holes of the lamp bracket from behind. 

3.

 

Fasten the 2 x washers, lock washers and nuts onto 

the front of the U-Bracket at the inner side of the 
lamp bracket to secure the lamp in position. Repeat 

steps 2 and 3 with second U-Bracket. 

4.

 

Optional Tilt 

 loosen the 2 x screws on both sides 

of the lamp to adjust the lamp angle. Adjust up to 20 

degrees upwards and 10 degrees downwards. Re-
tighten screws when positioned at desired angle. 

 

 
 
 

 
 
 

 
 

 
LAMP POST 

 Angled Pole (50mm diameter) 

 

TURN ON THE LAMP PRIOR TO INSTALLATION (see modes & settings) 
 
 

1.

 

Remove the standard bracket via the 4 x socket 
screws / washer / lock washer with the allen key. 

2.

 

Loosen the 4 x bottom socket screws to adjust the 

inner pole entry bracket to match the pole. Note: 
push the inner adjustable bracket upwards so the 

inner edge clears the 50mm hole and to pull the 
loosened screws back to the fitting. Do not 
completely remove screws. 

3.

 

Insert the pole into the pole entry of the lamp to full 
depth. 

4.

 

Ensure the lamp is in the correct position and re-

tighten the four screws loosened in step 2 to lock the 
lamp into place on the angled pole. 

 

 
 

 
 

 

 

 

Page 2 of 4 

 