ULT20 - User’s manual_rev.A
20
Table 5
RS-485
Symbol of
parameter
Description
Scope of changes
Adres
Address of the transducer in network
1...247
ModeUnit
Type of data transmission frame.
Value Description
r8n1
Eight bits of data, no parity checking, one
stop bit
r8n2
Eight bits of data, no parity checking, two
stop bits
r8o1
Eight bits of data, parity checking, (odd
parity) one stop bit
r8e1
Eight bits of data, parity checking, (parity)
one stop bit
BaudeRate
Rate of transmission expressed in b/s.
9600
14400
19200
28800
38400
57600
115200
Table 6
SYSTEM
Symbol of
parameter
Description
Scope of changes
Time
Current time according to internal
clock
00:00:00...23:59:59
Data
Current date according to internal
clock shown as YY-MM-DD,
where:
YY – current year,
MM – current month,
DD – current day.
00-01-01...99-12-31
AutoTime
Automatic day saving time
Value Description
Enabled Function
disabled.
Disabled
Automatic day saving time enabled.
LcdBright
Brightness of LCD display
backlight expressed as percentage
of maximum brightness.
0...100
LcdContr.
Contrast of LCD display.
0...63
LcdStyle
Style of LCD display/operation.
Value Description
Normal
Normal display – black characters on
white background