background image

 

www.LumaComfort.com 

S

ET 

U

I

NSTRUCTIONS

 

 

Carefully remove all packaging materials and retain for future storage/use. The 
air purifier arrives fully assembled, but the internal filters are packaged for 
shipping and must be unwrapped and reinstalled before use.  

 

a.

 

Open the air purifier’s front grill by placing your hand on top of the air 
purifier’s cover, inserting your finger in the slot on the side of the unit and 
by pulling the front cover out. 

b.

 

Unwrap the filters and ensure that all of the supplied filters are properly 
installed and in the correct order: carbon prefilter, HEPA filter, VOC filter, 
TiO2 mesh filter and UV (refer to parts list). Please note that the AP170W 
and AP400W models do not have the ionizer function. Never operate the 
air purifier without the HEPA filter properly installed.  

c.

 

Choose a suitable location for your air purifier. For best results, use the air 
purifier in an enclosed area with the doors and windows closed. Also, as a 
general rule, the closer your air purifier is located to the pollution source, 
the better the air purifying performance. 

d.

 

Position the air purifier near a power outlet and plug the connector end of 
the power cord into the power outlet.  

e.

 

We recommend running the unit on high speed for a few seconds before 
each use. After operating it on high speed, you may then adjust the unit to 
run at your desired speed. 

 

Содержание AP170W

Страница 1: ...Because you re not like everyone else AIR PURIFIER AP170W AP400W OWNER S MANUAL ...

Страница 2: ...e any questions or concerns regarding your product or if you would simply like to share an idea with us please feel free to contact us Our friendly and knowledgeable customer support team is here for you Call us today at 866 737 6390 or email support lumacomfort com For future reference we recommend you attach a copy of your sales receipt here and record the following information You will need thi...

Страница 3: ...echnical Support 10 Product Specifications 10 Troubleshooting 10 Warranty 11 SAVE THESE INSTRUCTIONS Please carefully read this manual before attempting to use this air purifier For your own safety comply with all safety instructions and warnings contained in this owner s manual to prevent personal injury or property damage For best results we recommend operating your air purifier 24 hours a day 7...

Страница 4: ... to fit into a matching receptacle Under no circumstances should the plug be altered in any way An improper connection can result in electric shock 10 If possible avoid using extension cords with this air purifier If an extension cord is absolutely necessary do not use more than one extension cord to operate more than one unit 11 Do not insert objects or allow fingers to enter into the air purifie...

Страница 5: ...articles down to 0 1 micron Activated carbon pre filter captures large dust particles and reduces cooking tobacco and pet odors Advanced photo catalyst TiO2 filter and UV light reduce organic pollutants such as formaldehyde benzene and ammonia as well as kill bacteria and viruses Modern flat panel design fits in with any decor Whisper quiet fan draws air into the unit without disturbing your envir...

Страница 6: ...HEPA filter VOC filter TiO2 mesh filter and UV refer to parts list Please note that the AP170W and AP400W models do not have the ionizer function Never operate the air purifier without the HEPA filter properly installed c Choose a suitable location for your air purifier For best results use the air purifier in an enclosed area with the doors and windows closed Also as a general rule the closer you...

Страница 7: ...n to turn on the automatic timer The timer can be set from 1 to 7 hours The air purifier will turn off once the set time has been reached d Press the UV button to turn on the UV function and press it again to turn this function off UV light is used to destroy organic contaminants such as viruses mold and bacteria e The filter indicator light will turn on when the filters need to be replaced After ...

Страница 8: ...ume will dramatically decrease at this time We recommend having a set of replacement filters on hand to ensure maximum performance a Before replacing any of the filters turn the air purifier off and unplug it from the power outlet b Open the air purifier s front grill by placing your hand on top of the air purifier s cover inserting your finger in the slot on the side of the unit and by pulling th...

Страница 9: ... cleaning Use a soft cloth and a mild soap and warm water solution to clean the unit s exterior particularly the air intake grills and air outlet Do not use harsh cleaners gasoline paint thinner benzene etc as these substances can damage the air purifier Thoroughly dry all of the air purifier parts with a soft cloth before reconnecting the unit to the power supply If the air purifier will not be i...

Страница 10: ...AP170W AP400W Product Dimensions 12 2 x 7 7 x 14 4 22 2 x 9 9 x 18 6 Product Weight 8 8 pounds 18 5 pounds Voltage 110V 120V 110V 120V Wattage 48W 100w Coverage Area 170 sq ft 500 sq ft Purification Methods HEPA filter carbon filter UV light TiO2 filter VOC filter Fan Speeds 3 Noise Level dB 53 25 52 4 50 5 57 2 51 6 48 6 Filter Life Indicator Yes Timer 1 7 hours Contaminants Removed Dust pollen b...

Страница 11: ... tear of parts that are designed to be replaced such as filters or batteries Power failure and improper power supply such as low voltage defective wiring or inadequate fuses Use of force or damage caused by external influences Complete or partially dismantled appliances THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY INCLU...

Отзывы: