background image

1

The Lucid ADA8824 (ADAT) Audio Interface is an eight-channel, 24-bit, A/D and D/A converter
intended for use with digital audio workstations. [For clarity the ADA8824 (ADAT) will be referred
to as the 8824 throughout the rest of this user’s guide.] The 8824 provides ADAT lightpipe connec-
tions, eight analog I/O channels, and eight AES/EBU digital I/O channels.

Designed specifically for Alesis lightpipe (fiber-optic) connections, the 8824 provides a plug and play
audio interface between your studio’s audio gear and the Apple Macintosh or Windows computers.
Created in a strategic partnership with Alesis Corporation, the 8824 delivers the flexibility and
performance you need for leading-edge audio production by providing eight channel digital transfers at
24-bit resolution. Digitally controlled attenuation of analog input and output levels and high-resolu-
tion LED metering help you realize the maximum dynamic range from your digital audio system.

Alesis pioneered the use of fiber-optic connections for digital audio transfer through its proprietary
format. The Alesis PCR card works on Macintosh and Windows computers and is compatible with
products from a wide range of vendors. The growing popularity of ADAT-equipped gear and the
introduction of the 8824 make it even easier for you to stay in the digital domain throughout most of
the production process.

The 8824’s analog I/O channels are equipped with XLR connectors, which accept or deliver either
balanced or unbalanced signals. The AES/EBU digital I/O channels use XLR connectors and the
lightpipe connections use TOSLINK connectors. The 8824 operates at +4dBu, -10dBV, and
intermediate signal levels.

We recommend that you read this manual from cover to cover. Somewhere between the confines of
the two covers you should find the answers to most of your questions, both technical as well as
musical. Please feel free to contact us if you have questions, comments or suggestions.

Phone:

425.742.1518

Fax:

425.742.0564

Email:

[email protected]

I

NTRODUCTION

S

ECTION

 1

50Hz-60Hz AC INPUT 40 WATTS MAX.

115V

RISK OF FIRE, REPLACE ONLY WITH SAME TYPE FUSE.

CAUTION: FOR CONTINUED PROTECTION AGAINST

ADA8824

ANALOG INPUTS

ANALOG OUTPUTS

OUT

MIDI

INPUT

OUT/THRU

AES/EBU DIGITAL INPUTS

INPUT

INPUT

OUT/THRU

OUTPUT

AES/EBU DIGITAL OUTPUTS

S/P DIF

WORD CLOCK

IN

ADAT OPTICAL

8

8

INPUT

OUTPUT

7

4 5 6

2

1

3

FOR OPTIONS

6

7

4

5

2

3

1

CONFIGURATION

REFER TO USER’S GUIDE

SYNC

ADAT

1

1

2

3

4

6

7

8

5

4

3

2

8

7

6

5

1-2

3-4

5-6

7-8

5-6

3-4

1-2

7-8

ANALOG IN

DIGITAL IN

ANALOG OUT

DIGITAL OUT

-1
-3

-9

-15

-12

-6

-1
-3

-1
-3

-9

-15

-12

-9

-15

-12

-6

-6

-21

-27

-24

-30

-50

-40

-21

-27

-24

-21

-27

-24

-30

-50

-40

-30

-50

-40

-18

-18

-18

24-BIT I/O

ADAT OPTICAL INTERFACE

-60

-60

-60

0

0

0

-1
-3

-9

-15

-12

-6

-1
-3

-9

-15

-12

-6

-21

-27

-24

-30

-50

-40

-21

-27

-24

-30

-50

-40

-18

-18

-1
-3

-1
-3

-9

-15

-12

-9

-6

-6

-12
-15

-21

-27

-24

-30

-50

-40

-40
-50

-30

-24
-27

-21

-18

-18

-60

-60

-60

-60

48 kHz

44.1 kHz

WORD CLK

AES/EBU

0

0

0

0

ADA

7

6

8

5

3

4

2

1

TECHNOLOGY

l

d

i

c

u

8824

METERING

SYNC

Содержание ADA8824

Страница 1: ...ADA8824 A D D A Platform ADAT Interface User s Guide...

Страница 2: ...ty 29 Rev A 0 June 1 1999 Lucid Technology part number 53ADAT1A00 Specifications subject to change without notice 1999 Lucid Technology All rights reserved Lucid is a registered trademark of Symetrix...

Страница 3: ...analog I O channels are equipped with XLR connectors which accept or deliver either balanced or unbalanced signals The AES EBU digital I O channels use XLR connectors and the lightpipe connections us...

Страница 4: ...OR SAFETY SUMMARY AVIS NE PAS OUVRIR Il ne se trouve a l interieur aucune piece pourvant entre repar e l usager SEE OWNERS MANUAL VOIR CAHIER D INSTRUCTIONS S adresser a un reparateur comp tent RISQUE...

Страница 5: ...correct value is 1 2A 250VAC slow blowing Bussman type GDC 500MA For 230VAC operation the correct value is 1 4A 250VAC slow blowing BussmantypeGDC 250MA Operating Location Do not operate this equipmen...

Страница 6: ...your audio system each system s grounding is totally separate and isolated There isn t nearly enough room on the interface card s mounting bracket to house suitable connectors The rear panel of the 88...

Страница 7: ...channels Connect the lightpipe connectors to and from your computer s lightpipe interface card There is no provision within the unit to operate the lightpipe connectors in thru mode MIDI Connections...

Страница 8: ...IF connectors to consumer audio digital inputs Connect the Word Clock input connector to a source of digital audio word clock Connect the Word Clock output connector to any other unit requiring the wo...

Страница 9: ...meters Refer to Table 1 In Remote mode the arithmetic sum of the bit values of these switches SW5 7 sets the MIDI device number 0 7 SW8 switches the MIDI command input between the ADAT Sync input and...

Страница 10: ...locks one for channels 1 2 3 4 5 6 7 8 A D Sync Source Select from the following ADAT Word Clock Internal 44 1kHz internal 48kHz AES 1 2 AES 3 4 AES 5 6 S PDIF The 8824 locks its clock to the selected...

Страница 11: ...dBV signals At 0dB of gain an input signal of 4dBu corresponds to a reading of 0dBFS as read on the 8824 s meter These readings are based on the use of sinewaves The same gain relationship applies at...

Страница 12: ...TECHNOLOGY l d i c u 8824 METERING SYNC 48 kHz 44 1 kHz WORD CLK AES EBU 1 SYNC LED Meters 15 segment LED bargraph meters display digital or analog signal levels from either input or output The sourc...

Страница 13: ...ts UP is analog Down is ADAT The optical output source switch determines whether the source for the optical output is the AES EBU or analog output signals UP is AES DOWN is analog The meter source sel...

Страница 14: ...e is 20 kilohms balanced diff amp input The maxi mum input level is 25 dBu This connector should be driven from a low source impedance Analog Outputs XLR 3 male connector This connector delivers balan...

Страница 15: ...l outputs If the AES EBU outputs are fed from the analog inputs the word clock output gets its signal from the A D sync source If the AES EBU outputs are fed from the ADAT optical input the word clock...

Страница 16: ...ution for low levels but higher headroom Of course if the signal is already recorded then it s just a matter of getting levels set properly and then making the transfer into your workstation It s conc...

Страница 17: ...de and z1 through zn is the data associated with the command the length varies depending on the command Command information Set Mode F0 00 00 5E 58 x 20 z F7 where z is defined as follows Bit 0 Analog...

Страница 18: ...a 20dBFS input translates to approximately 10dBV In both of these cases the actual headroom before clipping depends on the inputs of the mixer power amplifier etc that the 8824 is driving Set digital...

Страница 19: ...1 11 21 01 00 00 00 0B 00 00 00 00 03 00 02 28 31 11 21 01 00 00 00 2B 00 00 00 00 03 00 02 48 31 11 21 01 00 00 00 4B 00 00 00 00 03 00 02 68 31 11 21 01 00 00 00 6B 00 00 00 00 03 00 02 Not indicate...

Страница 20: ...ignal Note You can not record 24 bit signals onto a DAT recorder unless your DAT machine is one that has 24 bit recording capability The DAT format is 16 bit by design Trying to record longer word len...

Страница 21: ...ical I O In this application the 8824 operates as an eight channel 24 bit A D and D A converter connected to a host computer equipped with an ADAT lightpipe I O card Refer to figures at right The DIP...

Страница 22: ...detailed discussion of the 8824 s dip switch settings The screen shot of the configuration applica tion shows the selections made to make this application scenario operate in Remote mode Note that it...

Страница 23: ...analog audio and AES EBU digital signal pairs Refer to figures at right The DIP switch settings shown are for operation in Local mode Refer to page 7 for a detailed discussion of the 8824 s dip switch...

Страница 24: ...ion in Local mode Refer to page 7 for a detailed discussion of the 8824 s dip switch settings The screen from the configuration application shows how to configure the units via computer There are thre...

Страница 25: ...OCAL MODE REAR DIP SWITCH MASTER 7 8 6 5 7 5 6 8 4 3 1 2 1 4 3 2 8 7 6 5 3 2 1 4 REAR DIP SWITCH 8 7 6 4 3 2 1 5 ALL LOCAL MODE SLAVE C B A 8 7 5 6 8 6 5 7 4 2 3 1 2 3 4 1 8 7 5 6 8 6 5 7 4 2 3 1 2 3...

Страница 26: ...X X Number True Voice X X Velocity NoteON X X NoteOFF X X After Key s X X Touch Ch s Pitch Bender X X Control X X Change Program Change True X X System Exclusive O O System Song Pos X X Song Sel X X...

Страница 27: ...48 kHz WORD CLK 30 50 40 60 30 50 40 60 30 50 40 60 AES EBU 0 18 30 40 50 60 21 27 24 12 15 9 3 6 1 SIGNAL ATTENUATORS SIGNAL ATTENUATORS ATTENUATORS SIGNAL ATTENUATORS SIGNAL CONVERTERS D A D A CONV...

Страница 28: ...Maximum input level 25 dBu Maximum output level 25 dBu open circuit Performance Data Analog to Digital Conversion 24 bit delta sigma Signal to Noise Ratio A weighted 113dBFS THD Noise 0 005 0dBFS 1kHz...

Страница 29: ...interest of continuous product improvement Lucid Technology reserves the right to alter change or modify these specifications without prior notice Note The maximum operating ambient temperature is 25...

Страница 30: ...ect The foregoing warranties are in lieu of all other warranties whether oral written express implied or statutory LucidTechnology expressly disclaims any IMPLIED warranties including fitness for a pa...

Страница 31: ...etic compatibility Generic emission standard Part 1 Residential commercial and light industry EN 55103 2 Electromagnetic compatibility Generic immunity standard Part 1 Residential commercial and light...

Страница 32: ...30 Lucid Technology 14926 35th Avenue West Lynnwood WA 98037 USA Tel 425 742 1518 Fax 425 742 0564 Email lucid lucidtechnology com Website www lucidtechnology com...

Отзывы: