Administering a Stinger System
Managing administrative access to the unit
Stinger®
Administration Guide
1-11
Specifying the maximum number of login attempts
To specify the maximum number of login attempts that a user can make, set the
maximum-login-attempts
parameter in the
system
profile. Specify a number between
1 through 6. The default value is 3.
The system generates a log message whenever a login attempt fails. The log message
indicates whether the level of authentication failure is at the first level or second
level. For example:
LOG critical, Shelf 1, Controller, Time: 16:46:32--
login failure: user 'john', source '135.17.134.39' on first level access
or
LOG critical, Shelf 1, Controller, Time: 16:47:17--
login failure: user 'mitch', source '135.17.134.39' on second level access
If a user fails to login after making the number of attempts specified by the
maximum-
login-attempts
parameter, the system generates the
maxTelnetAttempts
trap.
Authentication from a remote shelf to a host Stinger unit
When a user opens a session from a remote shelf (Stinger MRT or Compact Remote)
to a host Stinger unit using the
open
shelf
slot
command, the systems creates a
terminal session using the control bus.
The host Stinger unit authenticates a user by prompting the user for a user name and
password. The user name and password must be defined in a
user
profile in the host
Stinger system. The host grants access to the user only after successful authentication,
and the host Stinger unit logs a message for every successful login and for every login
failure.
If the host unit is configured for two-level authentication or control bus access, the
host requires the user to log in twice.
No authentication is required when a user opens a session from the host Stinger unit
to any of its own slots or to a remote controller or remote LIM.
The following sample session shows a user logging in from a remote shelf to a host
unit. Two-level authentication is not configured on the host.
admin>
show
Shelf 2 ( slave ):
Reqd Oper Slot Type
{ shelf-2 slot-1 0 } N/A UP mrt-36-adsl-card
{ shelf-2 trunk-module-1 0 } UP UP oc3-atm-trunk-daughter-card
admin>
open 1 8
Usage: open - start session with master controller
User:
admin
Password:
shelf-router-1/8>
The following sample session shows a user logging in from a remote shelf to a host
unit. Two-level authentication is configured on the host Stinger unit.
admin>
open 1 8
Usage: open - start session with master controller
Содержание Stinger
Страница 1: ...Stinger Administration Guide Part Number 7820 0712 008 For software version 9 7 0 August 2004 ...
Страница 4: ......
Страница 16: ......
Страница 18: ......
Страница 62: ......
Страница 82: ......
Страница 96: ......
Страница 182: ......
Страница 218: ......
Страница 236: ......
Страница 252: ......
Страница 288: ......
Страница 350: ......
Страница 362: ......
Страница 374: ......