Watchdogs, Alarms, and Traps
Defining alarms
Stinger®
Administration Guide
8-11
Sample alarm configuration for remote shelf 3 state change
The following commands set an alarm for a change in status of shelf 3:
HOST>
new alarm shelf-3
HOST>
set enabled = yes
HOST>
set event = remote-shelf-state-change
HOST>
set physical-address shelf = shelf-3
HOST>
write -f
If the alarm is triggered (for example, if shelf 3 becomes unavailable), an emergency
log message is displayed. For example:
LOG emergency, Shelf 1, Controller-1, Time: 14:26:35--
Wed Sep 17 14:26:35 2000 - ALARM: Remote Shelf { 3 } Alarm is: Active
The following alarm command shows that an alarm has been set and the remote shelf
is down:
HOST>
alarm -s
Type Address State
Remote Shelf Down { 3 } Active
When the shelf changes state again, for example, when it comes up or is disabled in
the
remote-shelf-config
profile, the alarm is cleared. for example:
LOG emergency, Shelf 1, Controller-1, Time: 14:28:16--
Wed Sep 17 14:28:16 2000 - ALARM: Remote Shelf { 3 } Alarm is: Cleared
HOST>
alarm -s
Type Address State
external-fan-failure
A sensor on the remote shelf indicates failure of the
external fan unit. The failed status is shown in the
external-fan-unit-failed
setting of the
remote-shelf-stat
profile.
input-relay-closed
Contact-closure sensors on the remote shelf indicate
closure. The status is shown in the
contact-closure[
N
]
setting of the
remote-shelf-stat
profile.
input-relay-open
Contact-closure sensors on the remote shelf indicate
loss of contact closure. The status is shown in the
contact-closure[
N
]
setting of the
remote-shelf-stat
profile.
over-temperature-relay
A temperature sensor on the remote shelf indicates an
over-temperature condition. The status is shown in the
over-temperature
setting of the
remote-shelf-stat
profile.
door-open
A sensor on the remote shelf indicates that the door has
been opened.The status is shown in the
door-open
setting of the
remote-shelf-stat
profile.
Table 8-2. Compact Remote alarm events
Alarm event definition
Event on remote shelf that triggers alarm
Содержание Stinger
Страница 1: ...Stinger Administration Guide Part Number 7820 0712 008 For software version 9 7 0 August 2004 ...
Страница 4: ......
Страница 16: ......
Страница 18: ......
Страница 62: ......
Страница 82: ......
Страница 96: ......
Страница 182: ......
Страница 218: ......
Страница 236: ......
Страница 252: ......
Страница 288: ......
Страница 350: ......
Страница 362: ......
Страница 374: ......