Enclosure and Component Installation
Status lights
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
3
-43
COP status lights
On the COP, the FAULT status light turns ON briefly at startup. If the MAJOR status
light remains on, or turns on during operation of the unit, it indicates a failure.
Figure 3-33 shows the locations of the COP status lights.
MAJOR
Red
ON or
blinking
A major alarm condition has been detected.
For information about configuring major
alarms, see the Stinger Administration Guide.
The MAJOR status light turns ON at startup. It
then blinks slowly while the IP2000 or control
module runs its POST in the boot loader. It
continues to blink while the module loads its
operational code from the PCMCIA flash card.
It stops blinks and remains OFF when the code
is loaded successfully and POST is completed.
If the MAJOR status light continues to blink, it
indicates a failure.
MINOR
Red
On
A minor alarm condition has been detected.
For information about configuring minor
alarms, see the Stinger Administration Guide.
The MINOR status light is ON at startup. It
remains ON until the IP2000 or control
module passes all POST tests. It then stays OFF
until a minor alarm occurs.
If the IP2000 or control module fails POST, the
MINOR status light remains ON.
TRUNK
STATUS
Green
ON
Not used on the Stinger CR.
Indicates that the corresponding port on a
trunk module is fully operational.
MASTER
Green
ON
Indicates that this IP2000 or control module is
the master (primary) chassis controller.
(Always ON in the Stinger CR ATM DSLAM.)
Table 3-4. Status lights on the IP2000 module (continued)
Status
light
Color
Condition Indicates