Safety-Related Electrical, Physical, and Environmental Information
Site specifications
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
D-9
Site specifications
Stinger units require a particular operating environment and minimum clearance for
proper operation.
Operating environment
Table D-4 describes the environmental requirements for selecting an installation site
for the Stinger CR hardware. The site requirements are based on Network Equipment
Building System (NEBS) GR-63-CORE and GR-1089-CORE.
Physical characteristics
Basic unit includes one populated Stinger CR chassis
(cooling fan module, control and optics pack, power
supply, and three 48-port LIM/LPM pairs), in an outdoor
chassis with protector blocks and cabling.
Enclosure size
1
Height (enclosure only): 30.1 inches (76.5cm)
Height (overall): 40.5 inches (102.9cm)
Depth (enclosure only):
hosted units—11.5 inches (29.2cm)
stand-alone units—12 inches (30.5cm)
Depth (overall): 12.6 inches (32cm)
Width (enclosure only): 16.2 inches (41.2cm)
Width (overall): 20.5 inches (52cm)
Unit weight
121 pounds (54.885kg) maximum (with fans, power
supply, protections blocks, and cables)
1.
The overall measurements include clearance for cabinet hardware, locking mechanism, ventilation
shrouds, and cable cover.
Table D-3.
Stinger CR physical specifications (Continued)
Specification
Description
Table D-4. Stinger CR site specifications
Parameter
Requirement
Ambient operating
temperature
Light gray enclosures (fully populated:
-40°C to 46°C (-40°F to 114.8°F)
Green enclosures with IP2000 modules and 2
LIM/LPM circuit packs (maximum):
-40°C to 46°C (-40°F to 114.8°F)
Brown or green enclosures (fully populated):
-40°C to 40°C (-40°F to 104°F)
Relative humidity
10% to 95% (noncondensing)
Operating altitude
To 13,123 feet (4000 m)