Hosted System Configuration
Introduction to the host management interface
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
5-3
The decimal value of validation ID is the total of all decimal values for DIP switches
that are set to ON. For example, the binary 8-bit ID number created by setting only
DIP switches 1 and 2 ON is 11000000. The decimal value of the validation ID
produced by this setting is 192. This setting is shown in Figure 5-2.
Figure 5-2. Setting the Validation ID DIP switch
Use the following procedure to set the chassis validation ID DIP switch:
1
Verify that power has been removed from the Stinger CR ATM DSLAM unit.
2
Remove the cooling unit as described in “Replacing the chassis cooling module”
on page 3-26.
3
Use a small probe or jewelers screwdriver to set the desired DIP switches.
4
Replace the cooling module as described in “Replacing the chassis cooling
module” on page 3-26.
Introduction to the host management interface
All provisioning and management of a hosted Stinger CR ATM DSLAM is performed
on the host. You can
telnet
to the host’s command-line interface through an
Ethernet port, or via the ATM management connection over the host system’s trunk
interface.
The look and feel of the host management interface is very similar to that of a stand-
alone system, except that some commands require that you specify a shelf ID in the
physical address of a slot or port. Also, the shelf ID displayed in the output of
commands indicates the shelf numbers assigned to remote Stinger CR ATM DSLAM
units. Some commands display extended information for multishelf system
management. For details, see “Monitoring the status of remote shelves” on page 6-5.
The
show
command includes information about all shelves with an active control
channels to the host. The following command output shows that in addition to the
host shelf (shelf ID 1), shelf 2 has an active control channel to the host.
HOST>
show
Shelf 1 ( master ):
Controller { first-control-module } ( PRIMARY ):
Reqd Oper Slot Type
{ second-control-module } UP DOWN ( SECONDARY )
{ shelf-1 slot-1 0 } UP UP stngr-olim-card
{ shelf-1 trunk- UP UP oc12-atm-trunk-daughter-card
{ shelf-2 slot-2 0 } UP UP stngr-48-gs-adsl-card
ON