Error conditions related to SELT and DELT
Line testing
............................................................................................................................................................................................................................................................
363-217-018R9.8
Issue 1, August 2005
6 - 1 7
............................................................................................................................................................................................................................................................
Error conditions related to SELT and DELT
Error conditions during testing
The system generates error messages when you attempt to initiate a SELT or DELT
operation under one of the following conditions:
•
The port is disabled.
•
The port is active (in the
l i n e - d i a g
profile for the port,
e n a b l e d
is set to
y e s
).
•
A previous SELT, DELT, or a TFTP transfer is still in progress on the slot.
•
The LIM is not ADSL2/ADSL2+ capable.
•
A built-in self-testing (BIST) operation is running the port.
•
SELT or DELT test results are waiting for TFTP transfer on the slot. (The TFTP timer
is still running.)
•
Attempting a DELT test, if the
l i n e - c o d e
parameter in the line profile is not set to
a d s l 2
.
Error conditions during transfer of results
The system generates error messages when you attempt TFTP transfers under the
following conditions:
•
A SELT or DELT test is in progress.
•
A previous TFTP transfer is in progress on this Stinger system (shelf).
•
The TFTP server is unreachable.
•
File creation was blocked on the TFTP server.
•
No test result data was available.
Содержание STGRCR-ELIM-AP-48
Страница 5: ...Contents v 363 217 018R9 8 Issue 1 August 2005 Built in self testing BIST 6 20 IN Index ...
Страница 6: ... Contents v i 363 217 018R9 8 Issue 1 August 2005 ...
Страница 8: ... List of Figures v i i i 363 217 018R9 8 Issue 1 August 2005 ...
Страница 12: ... About This Information Product x i i 363 217 018R9 8 Issue 1 July 2005 ...
Страница 42: ... Power level parameters Interface profile and power parameters 2 1 2 363 217 018R9 8 Issue 1 August 2005 ...
Страница 60: ... Configuring call control Configuring an ADSL Annex A LIM 3 1 8 363 217 018R9 8 Issue 1 August 2005 ...
Страница 66: ... Examples for configuration of ADSL2 line codes Configuration Examples 4 6 363 217 018R9 8 Issue 1 August 2005 ...
Страница 98: ... Built in self testing BIST Line testing 6 2 2 363 217 018R9 8 Issue 1 August 2005 ...