Power-level parameters
Interface profile and power parameters
............................................................................................................................................................................................................................................................
363-217-018R9.8
Issue 1, August 2005
2 - 1 1
............................................................................................................................................................................................................................................................
Power-level parameters
Maximum power level definition
Maximum aggregate power level is the maximum output power allowed on the line at the
transmitter output. This value is expressed in decibels with reference to one milliwatt
(dBm), where zero dBm equals 1 milliwatt. It is defined for both directions.
Default settings
The
l i n e - c o n f i g
subprofile parameters, shown with their default values, for
configuring power:
[in AL-DMT/{ any-shelf any-slot 0 }:line-config]
max-aggr-power-level-up = 13
max-aggr-power-level-down = 20
max-power-spectral-density = 40
gain-default = 16-db
Important!
If you lower the default value, the line consumes less power and has less
capacity. The default value is the maximum allowed setting.
Parameter descriptions
Parameter
Description
max-aggr-power-level-up
Not used.
max-aggr-power-level-down
Specifies the maximum aggregate power level on the
downstream channel. Its effective range is from 8dBm
through 20dBm.
Important!
This setting is not used with the low-power
LIM card (STGRCR-LPM2-48-S). This LIM uses
minimum transmission power, which cannot be changed.
max-power-spectral-
density
Not used.
Important!
Downstream power is controlled by
changing the settings of the max-aggr-power-level-down
parameter.
gain-default
Not used.
Содержание STGRCR-ELIM-AP-48
Страница 5: ...Contents v 363 217 018R9 8 Issue 1 August 2005 Built in self testing BIST 6 20 IN Index ...
Страница 6: ... Contents v i 363 217 018R9 8 Issue 1 August 2005 ...
Страница 8: ... List of Figures v i i i 363 217 018R9 8 Issue 1 August 2005 ...
Страница 12: ... About This Information Product x i i 363 217 018R9 8 Issue 1 July 2005 ...
Страница 42: ... Power level parameters Interface profile and power parameters 2 1 2 363 217 018R9 8 Issue 1 August 2005 ...
Страница 60: ... Configuring call control Configuring an ADSL Annex A LIM 3 1 8 363 217 018R9 8 Issue 1 August 2005 ...
Страница 66: ... Examples for configuration of ADSL2 line codes Configuration Examples 4 6 363 217 018R9 8 Issue 1 August 2005 ...
Страница 98: ... Built in self testing BIST Line testing 6 2 2 363 217 018R9 8 Issue 1 August 2005 ...