DEFINITY ECS Release 6
System Description Pocket Reference
555-230-211
Issue 2
January 1998
Page 113
Technical Addendum
Maintenance Error Codes
(continued)
Technical Addendum
Error
Code
Description
Action
& '357(67127
&203/(7('
Slot did not complete
initializing.
& ):83*5$'($77(037
No action required.
& ):83*5$'(&203/(7(
No action required.
& ,19$/,')0:
'(7(&7('
:
Incompatibility problem;
specified video endpoint or
UDM is connected to an
008 or 408 MLX module
with firmware of vintage
0x29.
Replace 008 or 408 MLX
module with one of another
firmware vintage. Retire
permanent alarm manually.
& %$'%2$5'6,16<67(0
:
At least one incompatibility
problem of type HER
0x1C05 detected. Turns on
red LED on processor.
Replace 008 or 408 MLX
module with one of another
firmware vintage. Retire
permanent alarm manually.
&
See error code
& 7$&&(669,2/$7,21
:
T1 services (channels-
voice/data) administered
incorrectly.
Check facility provisioning
and re-administer channels
for voice or data. Ensure that
T1 data facilities are
accessed from data
terminals only (such as
UDMs or desktop video
systems) and that T1 voice
facilities are accessed from
telephones only (such as
MLX telephones).
& %HDUHU&DSDELOLW\
,QFRPSDWLELOLW\
A 64 kbps clear-channel
data call was routed to a
facility that does not have
sufficient bandwidth to
handle the call.
Verify that the ARS or UDP
routing tables route a data
call to a DS1 facility. Check
the DS1 Type administration
item for the specified facility.
If the administered value is
T1, the caller must initiate a
56 kbps call. Check the DS1
Suppression administration
item for the specified facility.
If the administered value
is
AMI-ZCS, the caller
must initiate a 56 kbps
call.