THERMASTRIP Installation Instructions
4 |
P a g e
INSTALLATION REQUIREMENT
•
The heaters are with plug (1800 & 2300W) and hardwired (3000W) version. Fixed wirings MUST BE
installed by a licensed electrician.
•
All wiring and installation of the appliance must adhere to the local council regulation and the latest local
and national wiring rules, eg. AS/NZS 3000 electrical installations.
•
Before installing SKU#209070 / 209071, check the installation location in the ceiling/wall has access to a
socket outlet that is connected to a wall switch. If it does not, please contact a licensed electrician to
arrange the installation of the socket outlet and wall switch before continuing. Refer to the circuit diagram
section for more information.
•
WARNING: Fire risk exists if the heater is covered by or positioned close to curtains or other
combustible materials.
•
WARNING: This heater is not equipped with a device to control the room temperature. Do not use
this heater in small rooms when they are occupied by persons not capable of leaving the room on
their own.
•
This product must be installed at least 2.2 m above the floor level. (Refer to figure 2.3)
•
This product is rated IP42 and it is suitable for the indoor and alfresco area.
When installed in the
alfresco area, it MUST BE installed fully undercover.
•
The mounting point must be able to support at least 4 times the weight of the heater.
•
Ensure all the clearance values to the structural building element are maintained according to the
clearance diagram. (Refer to figure 2)
•
Ensure the heater is kept at a safe distance from other furniture or appliances to avoid a hazard.
•
Do not place the product close to a radiant heat source.
•
Do not use in areas where gasoline, paint or other flammable liquids are used or stored.
•
Do not immerse the heater in liquid or allow liquid to enter the interior of the heater, as this could cause
an electric shock.
•
The heater must not be located immediately below a socket-outlet. (Refer to figure 3)
•
Seek assistance from a qualified electrician for any mechanical adjustments, service or repairs.
•
Do not touch the appliance with wet hands.
•
Do not connect the appliance to the mains voltage until it is fully installed in the desired position.
•
Do not use the appliance in the immediate surroundings of a bath/shower, swimming pool or any liquid
container.
•
Do not allow any cables, furnishings, flammable materials or other items to come in contact with any
surface of the heater.
•
If installed in wet areas, the heater switches or controls must be located so that they cannot be touched
by persons in the bath or shower.
•
WARNING: To prevent strangulation and shock hazard to children, the flexible wiring connected to
this appliance shall be effectively fixed to the wall.