background image

V1.0 (2021/08) 

 

 

 

 

 

 

 

 

LUCCI CONNECT 

RADIANT HEATER 

 

 

INSTALLATION 

 

OPERATION 

 

MAINTENANCE 

 

WARRANTY INFORMATION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

READ INSTRUCTIONS CAREFULLY FOR SAFE 

INSTALLATION AND FAN OPERATION.

 

Содержание 209070

Страница 1: ...V1 0 2021 08 LUCCI CONNECT RADIANT HEATER INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION...

Страница 2: ...pliance to heat up in an open environment to make the smell disappear IMPORTANT SAFETY PRECAUTIONS Always ensure the power is OFF and the heater has cooled down for at least 30 minutes before performi...

Страница 3: ...rchase for inspection or replacement Check whether the heater has been damaged during transport Do not operate install any product which appears damaged in any way Return the complete product to the p...

Страница 4: ...talled fully undercover The mounting point must be able to support at least 4 times the weight of the heater Ensure all the clearance values to the structural building element are maintained according...

Страница 5: ...d NOT be installed in the front of the heater or located at the back of the heater They should be located outside the physical footprint of the units to minimize heat build up behind the appliance The...

Страница 6: ...to make sure that there are no obstructions such as ceiling joists and there is sufficient clearance to the ceiling and wall Refer to figure 3 1 3 2 3 3 for the clearance requirement NOTE The heater...

Страница 7: ...THERMASTRIP Installation Instructions 7 P a g e NOTE The heater must also be kept away from the other appliances light fittings and the surface below as the clearance showed in Figure 3 4 Figure 3 4...

Страница 8: ...htening the screws Fig 3 1A NOTE Ensure the minimum distance of the two brackets is kept as Fig 3 1D 2 Install the other mounting bracket onto the wall or ceiling by the expansion nut or other appropr...

Страница 9: ...MASTRIP Installation Instructions 9 P a g e NOTE Minimum distance of the two mounting brackets Model L mm L1 mm 1800W SKU 209070 1240 1007 2300W SKU 209071 1540 1307 3000W SKU 209072 1840 1607 Figure...

Страница 10: ...wiring MUST BE installed by a licensed electrician for SKU 209072 NOTE The socket outlet and the switch are required for SKU 209070 209071 The socket outlet and switch MUST BE installed by a licensed...

Страница 11: ...wice until the 00 display Then press the UP DOWN button to set the timer The timer can be set between 1 hour and 24 hours When the time is set the system will automatically save and return to its norm...

Страница 12: ...n battery immediately call the 24 hour Poisons Information Centre on 13 11 26 for fast expert advice Battery Leaks Battery contains chemicals and should be treated as any chemical would Take precautio...

Страница 13: ...z Rated wattage 1800W 2300W 3000W Connection 1 5M Supply cord and plug 1 5M Supply cord only Mounting height 2 2 2 5 M Mounting Only installed with the mounting brackets provided Control options RF Re...

Страница 14: ...s a result of normal wear and tear 3 The product was installed by a licensed electrical contractor 4 A copy of the original receipt of purchase is presented 5 12 month warranty applies when used in an...

Страница 15: ...ur personal records and warranty purposes NAME ADDRESS POSTCODE MODEL NUMBER PO DATECODE Sticker here PO NUMBER or DATECODE DATE OF PURCHASE INSTALLING LICENSED ELECTRICIAN LICENCE No ATTACH PROOF OF...