Grenada Installation Instructions
5 |
P a g e
V3.0- EN– Published on
10. 2019 (Separate earth)
INSTALLING THE MOUNTING BRACKET
•
The ceiling fan must be installed in a location so that the blades are a minimum 300mm spacing from the
tip of the blade to the nearest objects or walls.
•
Secure the hanging bracket to the ceiling joist or structure that is capable of carrying a load of at least
30kg, with the two long screws provided. Ensure at least 30mm of the screw is threaded into the support.
NOTE: The bracket screws provided are for use with wooden structures only. For structures other
than wood, the appropriate screw type MUST be used. Ensure the screws used are suitable for the
mounting surface and the surrounding environment.
ANGLED CEILING INSTALLATION
This fan hanging system supports a maximum 20 degree
angled ceiling installation.
Fig. 3
Fig. 2