Installation Manual of HD-TVI Speed Dome 

 

ON

1

2

3

4

5

6

7

8

SW2

ON

1

2

3

4

5

6

7

8

SW1

 

Figure 2-4

 

Enlarged View of DIP Switch 

 

The default dome address is 0; the default baudrate is 2400; and the default value of the 120Ω 
terminator is OFF. 

 

 

Address Settings 

The SW1 switch is used for setting the address of speed dome. You can refer to Table 2-1 for details 
of setting the speed dome address to a specific number. 

Table 2-1

 

Set the Dome Address 

Dome 

Address 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

255 

ON 

ON 

ON 

ON 

ON 

ON 

ON 

ON 

 

 

Baudrate Settings 

The  No.  1,  2  and  3  of  SW2  switch  are  for  setting  the  baudrate  of  the  speed  dome,  standing  for 
2400bps, 4800bps and 9600bps respectively. The baudrate will be set as 2400bps by default if it is 
out of this range. Refer to the following table: 

Table 2-2

 

Set the Baudrate of the Dome 

DIP Switch SW2-Baudrate Settings 

Baudrate 

2400 

ON 

OFF 

OFF 

4800 

OFF 

ON 

OFF 

9600 

ON 

ON 

OFF 

19200 

OFF 

OFF 

ON 

 

 

Protocol Settings 

The speed dome is self-adaptive to PELCO-D, PELCO-P and private protocol which cannot set by the 
DIP switches. 
 

 

Communication Mode Settings 

The No. 7 of SW2 switch is for setting the RS485 communication mode of the dome to simplex or 

Содержание PTZH213X23

Страница 1: ...HD TVI Speed Dome Installation Manual...

Страница 2: ...ntact the dealer This manual is applicable to HD TVI Speed Domes This manual may contain several technically inaccurate points or printing errors and the content is subject to change without notice Th...

Страница 3: ...erence received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied accessories too are marked with CE and comply therefore wi...

Страница 4: ...cted on the power socket When the product is installed on wall or ceiling the device shall be firmly fixed If smoke odors or noise rise from the device turn off the power at once and unplug the power...

Страница 5: ...at the same time Please use the provided glove when open up the dome cover avoid direct contact with the dome cover because the acidic sweat of the fingers may erode the surface coating of the dome c...

Страница 6: ...DIP Switch Settings 8 2 3 Wiring and Installation 10 2 3 1 Wiring 10 2 3 2 Installing the Bracket 10 2 3 3 Set the DIP Switch 12 2 3 4 Installing the Speed Dome 12 Appendix 14 Appendix 1 Lightning Sur...

Страница 7: ...the dome and the mount Preparing Cables Choose the video cable according to the transmission distance the minimum requirement for the coaxial video cable are shown as follows 75 impedance 100 copper c...

Страница 8: ...eparation Wiring Installing Bracket Setting DIP Switch Installing Speed Dome Connecting Cables Power on Self test End Succeeded Failed No Yes Figure 2 1 Installation Flow Diagram 2 1 Cable Description...

Страница 9: ...RS485 485 control VIDEO Coaxial and analog video output 2 2 DIP Switch Settings Two DIP switches SW1 and SW2 are for setting the speed dome address baudrate protocol etc with value ON 1 and OFF 0 The...

Страница 10: ...F ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 255 ON ON ON ON ON ON ON ON Baudrate Settings The No 1 2 and 3 of SW2 switch are for setting the baudrate of the speed dome standing for 24...

Страница 11: ...n environment and planning the wiring is highly recommended before the accurate deployment of the wire is implemented in order to provide a safe and steady power supply and a reasonable wiring route G...

Страница 12: ...own in the figure below Figure 2 5 Wall Mount Bracket Nuts and Flat Washers 2 Drill 4 screw holes in the wall according to the holes of the mount and then insert M8 expansion screws not supplied into...

Страница 13: ...refer to the Section 2 2 DIP Switch Settings for DIP switch settings 2 3 4 Installing the Speed Dome The sketched of installing the speed dome are for reference only Steps 1 Hang the safety rope to t...

Страница 14: ...Installation Manual of HD TVI Speed Dome 13 Figure 2 9 Tighten the Lock Screws...

Страница 15: ...g protection apparatus and lightning conductor are necessary to be added The design of lightning protection and grounding of the outdoor devices and cables should be considered together with the light...

Страница 16: ...ference situation or there are lots of devices are added to the bus on the contrary the transmission distance will be increased Connection Methods RS485 industry bus standard require daisy chain conne...

Страница 17: ...roubleshooting of RS485 communication Problem Possible Reasons To Solve the Problem The speed dome does the self test action but cannot be controlled remotely 1 The address or baudrate of the speed do...

Страница 18: ...Solve the Problem dome can be controlled but not smoothly tightly 2 RS485 or RS485 wire is broken 2 Change a RS485 wire 3 The speed dome is too far away from the remote control device 3 Add a terminal...

Страница 19: ...ed as the minimum wire gauge 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 1...

Страница 20: ...e mm American Wire Gauge AWG British Wire Gauge SWG Cross sectional Area of Bare Wire mm2 0 750 21 0 4417 0 800 20 21 0 5027 0 900 19 20 0 6362 1 000 18 19 0 7854 1 250 16 18 1 2266 1 500 15 17 1 7663...

Отзывы: