Ethernet
The submenu Ethernet corresponds to the device menu Config → Network. This submenu sets the
following settings:
Selection
Meaning
Receive protocol
Setting the receiving data protocol:
Art-Net
ShowNet
AVAB/IPX
sACN
AVAB/UDP
Send protocol
Setting the transmission data protocol:
Art-Net
ShowNet
AVAB/IPX
sACN
AVAB/UDP
Light timeout
Setting the timeout for receiving data 1 to 999s
Network send
rate
Setting the minimum transmission rate for data packets, if there is no chang-
ing of the values:
20ms, 40ms, 80ms, 100ms, 200ms, 500ms, 1s, 2s, 3s, 4s
IP Mode
Getting the IP address:
Manual:
Free adjustment
Art-Net
2:
Art-Net
address for 2 network
Art-Net
10:
Art-Net
address for 10 network
DHCP:
If a DHCP server is on the network
IP Address
IP address
If "IP Mode = Manual" manual adjustment is possible.
Subnet mask
Netmask
If "IP Mode = Manual" manual adjustment is possible.
GW
Gateway
Usually changing the preset address is not necessary.
Содержание MasterPort 2
Страница 5: ...MasterPort 2 LSS 5 Preamble...
Страница 8: ...MasterPort 2 8 The MasterPort 2...
Страница 13: ...MasterPort 2 LSS 13 Screens and Configuration...
Страница 17: ...MasterPort 2 LSS 17 Configuration of the MasterPort 2...
Страница 32: ...MasterPort 2 32 Config Network In the submenu Network all protocols based on Ethernet will be set...
Страница 36: ...MasterPort 2 36 Options Display The settings for the screen and displays will be set in this submenu...
Страница 40: ...MasterPort 2 40 Configuration with LSS ConfigCore...
Страница 58: ...MasterPort 2 58 Service...
Страница 64: ...MasterPort 2 64 Appendix...